文献速递白内障与屈光手术

矫正环曲面人工晶状体位置不良的复位手术发生率与结局分析

Incidence and Outcomes of Repositioning Surgery to Correct Misalignment of Toric Intraocular Lenses.
PubMed 文献 · Ophthalmology · 2017-08-18

该回顾性多中心病例系列纳入8个手术中心6431只眼,其中42只眼(0.653%)接受环曲面人工晶状体复位手术,平均在植入后9.9±7.5天进行。复位手术显著减小了晶状体偏斜角度和残余散光,且手术间隔与残余偏斜呈负相关,作者据此建议在人工晶状体植入1周后行复位手术。

要点

  • 6431只眼中42只眼(0.653%)接受复位手术,平均在植入后9.9±7.5天进行。
  • 复位手术将偏斜从32.9°±15.7°降至8.8°±9.7°,残余散光从2.4±1.1D降至1.1±0.8D(均P<0.001)。
  • 白内障手术至复位手术的间隔与残余偏斜程度呈显著负相关(r=-0.439,P<0.001)。

核心结论

  • 环曲面人工晶状体复位手术发生率为0.653%,复位手术时机与手术结局存在关系,作者认为应在人工晶状体植入1周后行复位手术。

研究设计与样本

  • 回顾性多中心病例系列,纳入8个手术中心接受超声乳化联合环曲面人工晶状体植入的患者,通过查阅病历收集复位手术资料。

主要发现

  • 6431只植入环曲面人工晶状体的眼中,42只眼(0.653%)接受复位手术,平均于植入后9.9±7.5天(范围0-30天)进行。
  • 复位手术后偏斜从32.9°±15.7°降至8.8°±9.7°(P<0.001),残余散光从2.4±1.1D降至1.1±0.8D(P<0.001),测量于术后7.6±5.0周。
  • 白内障手术至复位手术的间隔与残余偏斜程度呈显著负相关(r=-0.439,P<0.001)。
  • 白内障术后6天内行复位手术者残余偏斜为13.1°±13.5°,7天及以上者残余偏斜为6.3°±5.9°(P<0.001)。
  • 白内障术后24小时内治疗的2只眼中,人工晶状体明显再旋转并需要额外手术干预。

关键数值与推荐

  • 环曲面人工晶状体复位手术发生率为0.653%(42/6431只眼)。
  • 复位手术将偏斜从32.9°±15.7°降至8.8°±9.7°,残余散光从2.4±1.1D降至1.1±0.8D(均P<0.001)。
  • 6天内复位者残余偏斜13.1°±13.5° vs 7天及以上者6.3°±5.9°(P<0.001)。

临床怎么用

  • 作者认为,环曲面人工晶状体复位手术应在人工晶状体植入1周后进行。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To analyze the incidence and appropriate timing of repositioning surgery to correct misalignment of acrylic foldable toric intraocular lenses (IOLs). DESIGN: Retrospective, multicenter case series. PARTICIPANTS: Patients who had undergone phacoemulsification and implantation of toric IOL at 8 surgical sites. METHODS: Patient charts were reviewed to collect data on repositioning surgery of toric IOLs. MAIN OUTCOME MEASURES: Incidence, timing, and outcomes of repositioning surgery. RESULTS: Among 6431 eyes implanted with toric IOLs, 42 eyes (0.653%) of 42 patients underwent repositioning surgery at an average of 9.9±7.5 days (range, 0-30 days) after IOL implantation. The repositioning surgery significantly reduced misalignment from 32.9°±15.7° to 8.8°±9.7° (P < 0.001), which was measured at 7.6±5.0 weeks postoperatively. Refractive cylinder was significantly reduced from 2.4±1.1 diopters (D) to 1.1±0.8 D (P < 0.001). There was a significant negative correlation between the interval from cataract surgery to repositioning procedure and the degree of residual misalignment (r = -0.439, P < 0.001). The residual misalignment was 13.1°±13.5° when the repositioning surgery was performed within 6 days after cataract surgery, whereas the residual misalignment was 6.3°±5.9° when the IOL was repositioned 7 days or later (P < 0.001). In 2 eyes that were treated within 24 hours after cataract surgery, the IOL re-rotated significantly, and additional surgical intervention was required. CONCLUSIONS: Toric IOLs were repositioned in 0.653% of cases. A relationship was found between the timing of repositioning surgery and surgical outcome. These data suggest that repositioning surgery should be performed 1 week after IOL implantation.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Oshika T, Inamura M, Inoue Y, et al. Incidence and Outcomes of Repositioning Surgery to Correct Misalignment of Toric Intraocular Lenses. Ophthalmology. 2017. PMID: 28827044. doi:10.1016/j.ophtha.2017.07.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。