文献速递青光眼

基于光学相干断层扫描分析预测青光眼患者Humphrey 24-2视野阈值

Optical Coherence Tomography Analysis Based Prediction of Humphrey 24-2 Visual Field Thresholds in Patients With Glaucoma.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

本前瞻性研究在112例早、中、晚期原发性及继发性开角型青光眼患者中,评估基于9视野OCT图像分析预测Humphrey 24-2视野敏感度阈值的四种算法。RGC-AC优化算法的平均相关系数R=0.74(95%CI 0.67-0.76)、均方根误差RMSE=5.42 dB(95%CI 5.1-5.7),显著优于其他三种模型。

要点

  • RGC-AC优化算法预测HVF 24-2阈值的平均R=0.74、RMSE=5.42 dB。
  • 该算法显著优于Naïve、Garway-Heath和Donut模型(P<0.05/3)。
  • 其预测性能接近HVF 24-2自身的可重复性。

关键数值与推荐

  • RGC-AC优化模型:平均R=0.74(95%CI 0.67-0.76),RMSE=5.42 dB(95%CI 5.1-5.7)。
  • Naïve模型:R=0.49(95%CI 0.44-0.54),RMSE=7.24 dB(95%CI 6.6-7.8 dB)。
  • Garway-Heath模型:R=0.66(95%CI 0.60-0.68),RMSE=6.07 dB(95%CI 5.7-6.5 dB)。
  • Donut模型:R=0.67(95%CI 0.61-0.69),RMSE=6.08 dB(95%CI 5.8-6.4 dB)。
  • RGC-AC优化模型显著优于其他三种模型(P<0.05/3)。

局限性

  • 15/112例因扫描少于9次被排除,11/97例因分割质量不足被排除。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: A pilot study showed that prediction of individual Humphrey 24-2 visual field (HVF 24-2) sensitivity thresholds from optical coherence tomography (OCT) image analysis is possible. We evaluate performance of an improved approach as well as 3 other predictive algorithms on a new, fully independent set of glaucoma subjects. METHODS: Subjects underwent HVF 24-2 and 9-field OCT (Heidelberg Spectralis) testing. Nerve fiber (NFL), and ganglion cell and inner plexiform (GCL+IPL) layers were cosegmented and partitioned into 52 sectors matching HVF 24-2 test locations. The Wilcoxon rank sum test was applied to test correlation R, root mean square error (RMSE), and limits of agreement (LoA) between actual and predicted thresholds for four prediction models. The training data consisted of the 9-field OCT and HVF 24-2 thresholds of 111 glaucoma patients from our pilot study. RESULTS: We studied 112 subjects (112 eyes) with early, moderate, or advanced primary and secondary open angle glaucoma. Subjects with less than 9 scans (15/112) or insufficient quality segmentations (11/97) were excluded. Retinal ganglion cell axonal complex (RGC-AC) optimized had superior average R = 0.74 (95% confidence interval [CI], 0.67-0.76) and RMSE = 5.42 (95% CI, 5.1-5.7) dB, which was significantly better (P < 0.05/3) than the other three models: Naïve (R = 0.49; 95% CI, 0.44-0.54; RMSE = 7.24 dB; 95% CI, 6.6-7.8 dB), Garway-Heath (R = 0.66; 95% CI, 0.60-0.68; RMSE = 6.07 dB; 95% CI, 5.7-6.5 dB), and Donut (R = 0.67; 95% CI, 0.61-0.69; RMSE = 6.08 dB, 95% CI, 5.8-6.4 dB). CONCLUSIONS: The proposed RGC-AC optimized predictive algorithm based on 9-field OCT image analysis and the RGC-AC concept is superior to previous methods and its performance is close to the reproducibility of HVF 24-2.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Guo Z, Kwon YH, Lee K, et al. Optical Coherence Tomography Analysis Based Prediction of Humphrey 24-2 Visual Field Thresholds in Patients With Glaucoma. Invest Ophthalmol Vis Sci. 2017. PMID: 28796875. doi:10.1167/iovs.17-21832