文献速递青光眼

视盘周围三维视网膜神经纤维层体积在青光眼中的诊断能力:基于光学相干断层扫描体积扫描

Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.
PubMed 文献 · Am J Ophthalmol · 2017-08-12

该研究评估光谱域光学相干断层扫描(OCT)体积扫描所得视盘周围三维视网膜神经纤维层(RNFL)体积对开角型青光眼(OAG)的诊断能力。共纳入180例受试者(113例OAG、67例正常者),每例取一眼,计算整体、象限与扇形区域的视盘周围三维RNFL体积(采用4种不同尺寸环带),并与二维RNFL厚度环扫比较。结果显示,最小环带的下方象限三维RNFL体积诊断能力最佳(AUROC值0.977),整体三维RNFL体积的AUROC值与整体二维RNFL厚度相当,差异无统计学意义。

要点

  • 最小环带的下方象限三维RNFL体积AUROC值达0.977,为所有参数中诊断能力最佳者。
  • 整体三维RNFL体积与整体二维RNFL厚度的AUROC值在4种环带尺寸下均相当,P值为.0593至.6866。
  • 整体RNFL体积比较中最小环带的AUROC值最佳(P值为.0317至.0380)。

核心结论

  • 视盘周围三维RNFL体积对青光眼检测表现出优异的诊断性能。
  • 视盘周围三维RNFL体积参数的诊断能力与视盘周围二维RNFL厚度测量相同或更优,但差异无统计学意义。

研究设计与样本

  • 研究类型为诊断准确性评估,地点为学术临床环境。
  • 研究人群共180例(113例开角型青光眼、67例正常受试者),每例受试者纳入一眼。
  • 采用光谱域OCT体积扫描计算整体、象限和扇形区域的视盘周围三维RNFL体积,使用4种不同尺寸环带,并获取视盘周围二维RNFL厚度环扫。

主要发现

  • 在所有二维和三维RNFL参数中,诊断能力最佳者为最小环带的下方象限三维RNFL体积(AUROC值0.977)。
  • 整体三维RNFL体积与整体二维RNFL厚度的AUROC值在全部4种环带尺寸下相当(P值为.0593至.6866)。
  • 整体RNFL体积4种环带尺寸比较中,最小环带的AUROC值最佳(P值为.0317至.0380)。
  • 最小尺寸环带可能具有最佳诊断潜力,部分原因在于没有因超出6×6 mm²扫描区域而被排除的区域。

关键数值与推荐

  • 最小环带下方象限三维RNFL体积AUROC值为0.977。
  • 整体三维RNFL体积与整体二维RNFL厚度AUROC值比较的P值为.0593至.6866。
  • 整体RNFL体积4种环带尺寸AUROC值比较的P值为.0317至.0380。
  • 扫描区域为6×6 mm²。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral-domain optical coherence tomography (OCT) volume scans for open-angle glaucoma (OAG). DESIGN: Assessment of diagnostic accuracy. METHODS: Setting: Academic clinical setting. STUDY POPULATION: Total of 180 patients (113 OAG and 67 normal subjects). OBSERVATION PROCEDURES: One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using 4 different-size annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios. RESULTS: Among all 2D and 3D RNFL parameters, best diagnostic capability was associated with inferior quadrant 3D RNFL volume of the smallest annulus (AUROC value 0.977). Otherwise, global 3D RNFL volume AUROC values were comparable to global 2D RNFL thickness AUROC values for all 4 annulus sizes (P values: .0593 to .6866). When comparing the 4 annulus sizes for global RNFL volume, the smallest annulus had the best AUROC values (P values: .0317 to .0380). The smallest-size annulus may have the best diagnostic potential, partly owing to having no areas excluded for being larger than the 6 × 6 mm2 scanned region. CONCLUSION: Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma. Peripapillary 3D RNFL volume parameters have the same or better diagnostic capability compared to peripapillary 2D RNFL thickness measurements, although differences were not statistically significant.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Khoueir Z, Jassim F, Poon LY, et al. Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans. Am J Ophthalmol. 2017. PMID: 28807732. doi:10.1016/j.ajo.2017.08.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。