文献速递眼底病与葡萄膜炎

健康眼与非增殖型糖尿病视网膜病变眼视锥细胞镶嵌反射特性随时间变化的分析

Analysis of Cone Mosaic Reflectance Properties in Healthy Eyes and in Eyes With Nonproliferative Diabetic Retinopathy Over Time.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

研究在5年内对12名健康受试者和6名轻度非增殖型糖尿病视网膜病变(NPDR)患者采集旁中心凹视锥细胞镶嵌的自适应光学图像,分析视锥强度直方图分布、纹理指标及两种新指标。结果显示两组视锥强度直方图分布相似,但视锥/视锥间强度、变差函数斜率和熵在健康眼与NPDR眼之间存在显著差异(P分别为0.036、0.002、0.014),除平均视锥强度外所有参数在本研究期间不随时间变化。

要点

  • 健康眼与轻度NPDR眼的视锥/视锥间强度、变差函数斜率和熵存在显著差异。
  • 除平均视锥强度外,其余参数在5年观察期内未随时间变化。
  • 变差函数被引入用于量化视锥反射空间分布及空间依赖性差异。

核心结论

  • 健康眼与NPDR眼在视锥镶嵌反射特性上存在显著差异,尤其体现在空间组织和强度上,特别是方向性与非方向性背向散射之间。

研究设计与样本

  • 研究在5年内对12名健康受试者和6名轻度NPDR患者采集旁中心凹视锥镶嵌的自适应光学图像。
  • 每个受试者在四个视网膜位置(200×200 μm区域,距中心凹2°,沿四条子午线)计算各指标。

主要发现

  • 两组视锥强度直方图分布相似。
  • 视锥/视锥间强度在健康眼与NPDR眼之间差异有统计学意义(P=0.036)。
  • 变差函数斜率在健康眼与NPDR眼之间差异有统计学意义(P=0.002)。
  • 熵在健康眼与NPDR眼之间差异有统计学意义(P=0.014)。
  • 除平均视锥强度外,所有参数在本研究期间不随时间变化。

关键数值与推荐

  • 视锥/视锥间强度健康眼 vs NPDR眼差异P=0.036。
  • 变差函数斜率健康眼 vs NPDR眼差异P=0.002。
  • 熵健康眼 vs NPDR眼差异P=0.014。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We investigate the reflectance properties of the cone mosaic in adaptive optics (AO) images of healthy subjects and subjects with nonproliferative diabetic retinopathy (NPDR) over time. METHODS: We acquired images of the parafoveal cone mosaic over 5 years in 12 healthy subjects and in six patients with mild NPDR. We analyzed the parameters of the cone intensity histogram distribution (mean, SD, and skewness), two metrics of the cone mosaic texture (sharpness and entropy), and two novel metrics (cone/intercone intensity and slope of the variogram). Each metric was calculated on the same four retinal locations (200 × 200 μm areas, 2° from the fovea along the four meridians) over time for each subject. RESULTS: The histogram distributions of cone intensities were similar between the two study groups. However, the cone/intercone intensity, slope of the variograms and entropy showed a significant difference between healthy and NPDR subjects (P = 0.036, P = 0.002, P = 0.014, respectively). All parameters, except for mean cone intensity, did not change with time in this study. CONCLUSIONS: We observed significant differences in cone mosaic reflectance properties between healthy eyes and eyes with NPDR, in its spatial organization and in its intensity, especially between directional and nondirectional backscattering. We introduced a novel method for the study of the spatial distribution of cone reflectance, the variogram, which was able to quantify differences of the spatial dependence of cone intensities over a short range between NPDR and healthy eyes.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Mariotti L, Devaney N, Lombardo G, et al. Analysis of Cone Mosaic Reflectance Properties in Healthy Eyes and in Eyes With Nonproliferative Diabetic Retinopathy Over Time. Invest Ophthalmol Vis Sci. 2017. PMID: 28820921. doi:10.1167/iovs.17-21932

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。