文献速递眼底病与葡萄膜炎

糖尿病性黄斑水肿荧光素眼底血管造影渗漏的分布:病因学新探

The Distribution of Leakage on Fluorescein Angiography in Diabetic Macular Edema: A New Approach to Its Etiology.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

连续纳入87例糖尿病性黄斑水肿患者的87只眼,在ETDRS网格各分区测量晚期荧光素眼底血管造影渗漏面积,并分析其与神经纤维层厚度的相关性。结果显示渗漏面积与神经纤维层厚度呈高度负相关(r=-0.96,95%CI -0.99至-0.02),提示神经纤维层内星形胶质细胞对防止内血视网膜屏障损伤起关键作用。

要点

  • 颞侧、上方、下方、鼻侧分区渗漏面积分别为3.96 mm2、3.03 mm2、2.84 mm2、2.34 mm2。
  • 仅颞侧分区在全部87例中均显示渗漏。
  • 渗漏面积与神经纤维层厚度呈负相关,r=-0.96(95%CI -0.99至-0.02)。

核心结论

  • 渗漏分布与神经纤维层厚度呈反向且具统计学意义的相关性,提示神经纤维层内星形胶质细胞在防止内血视网膜屏障损伤及糖尿病性黄斑水肿微动脉瘤形成中起关键作用。
  • 内血视网膜屏障损伤所致液体外渗在颞侧分区较其他三个分区更早出现。

研究设计与样本

  • 连续病例系列,纳入87例糖尿病性黄斑水肿患者的87只眼。
  • 在晚期荧光素眼底血管造影图像上测量早期糖尿病视网膜病变治疗研究(ETDRS)网格各分区的渗漏面积。
  • 神经纤维层规范厚度取自既往采用谱域光学相干断层扫描的研究工作。

主要发现

  • 鼻侧、下方、上方、颞侧分区的渗漏面积分别为2.34 mm2、2.84 mm2、3.03 mm2、3.96 mm2。
  • 除下方与上方分区之间外(P=0.65),其余每两个分区之间的渗漏面积差异均有统计学意义(P<0.05)。
  • 颞侧分区是唯一在全部87例中均显示渗漏的分区。
  • 渗漏面积与ETDRS各分区神经纤维层厚度呈负相关,且有高度统计学意义:r=-0.96(95%置信区间-0.99至-0.02)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine the distribution of leakage on fluorescein angiography (FA) and explore the clinically protective role of astrocytes against damage to the inner blood retinal barrier (iBRB) in diabetic macular edema (DME). METHODS: A consecutive case series of 87 eyes of 87 patients with DME was included. We measured the leakage area in each field of the Early Treatment Diabetic Retinopathy Study (ETDRS) grid on late-phase FA images. The normative thickness of the nerve fiber layer (NFL), in which the astrocytes are confined, was derived from a previous work using spectral-domain optical coherence tomography. We explored the difference in leakage areas in every two fields. Moreover, we investigated the correlation between the mean of the leakage area and the mean of thickness of the NFL in each ETDRS field. RESULTS: The leakage areas in the nasal, inferior, superior, and temporal fields were 2.34 mm2, 2.84 mm2, 3.03 mm2, and 3.96 mm2. The difference in leakage area between each two fields was significant in all cases (P < 0.05) except between the inferior and superior fields (P = 0.65). The temporal field was the only field that showed leakage in all 87 cases. The correlation between the leakage area and the thickness of the NFL in the ETDRS fields was negative and highly significant: r = -0.96 (95% confidence interval -0.99 to -0.02). CONCLUSION: The distribution of leakage correlates inversely and statistically significantly with the thickness of the NFL, suggesting astrocytes in the NFL play a pivotal role in preventing damage to the iBRB and subsequent evolution of microaneurysms in DME. Moreover, fluid extravasation due to damage to the iBRB is expressed earlier in the temporal than in the other three fields.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Haj Najeeb B, Simader C, Deak G, et al. The Distribution of Leakage on Fluorescein Angiography in Diabetic Macular Edema: A New Approach to Its Etiology. Invest Ophthalmol Vis Sci. 2017. PMID: 28796876. doi:10.1167/iovs.17-21510

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。