文献速递眼底病与葡萄膜炎

糖尿病牵引性与牵引-孔源性视网膜脱离修复术后的视功能与解剖结果

VISUAL AND ANATOMICAL OUTCOMES AFTER DIABETIC TRACTION AND TRACTION-RHEGMATOGENOUS RETINAL DETACHMENT REPAIR.
PubMed 文献 · Retina · 2018-01-01

该单中心回顾性研究纳入2009年11月1日至2015年1月1日在LAC+USC医学中心因增殖性糖尿病视网膜病变继发牵引性视网膜脱离行平坦部玻璃体切除术的403眼(359例患者)。一次手术后视网膜复位成功率87.6%,末次随访92.6%;末次随访最佳矫正视力提高两行及以上者占56.3%,稳定者占23.8%,下降两行及以上者占19.9%。23G与25G系统成功率与20G器械相似(P=0.73);使用硅油填充的眼一次手术复位率(77.6% vs. 87.6%;P=0.013)、末次随访复位率(85.7% vs. 92.6%;P=0.048)较低,视力下降率较高(34.7% vs. 19.9%;P<0.0001),但合并孔源性脱离(47.0% vs. 21.3%;P<0.0001)及黄斑受累(74.5% vs. 60.0%;P<0.0001)的比例更高。

要点

  • 一次手术视网膜复位率87.6%,末次随访达92.6%。
  • 末次随访视力提高或稳定者合计80.1%。
  • 23G/25G与20G玻璃体切除系统成功率相似(P=0.73)。

核心结论

  • 在这项大型单中心回顾性研究中,晚期糖尿病牵引性视网膜脱离经玻璃体切除术后解剖结果良好,80.1%的眼视力提高或稳定。
  • 较小口径玻璃体切除系统与20G器械的结果相似。

研究设计与样本

  • 单中心回顾性研究,利用手术记录回顾性识别2009年11月1日至2015年1月1日在LAC+USC医学中心因增殖性糖尿病视网膜病变继发牵引性视网膜脱离行平坦部玻璃体切除术的患者。
  • 共纳入403眼(359例患者)。

主要发现

  • 一次手术后视网膜成功复位者占87.6%,末次随访时复位者占92.6%。
  • 末次随访最佳矫正视力提高两行及以上者占56.3%,稳定者占23.8%,下降两行及以上者占19.9%。
  • 23G和25G玻璃体切除系统治疗眼与20G器械治疗眼的成功率相似(P=0.73)。
  • 硅油填充眼一次手术复位率较低(77.6% vs. 87.6%;P=0.013),末次随访复位率较低(85.7% vs. 92.6%;P=0.048),视力下降率较高(34.7% vs. 19.9%;P<0.0001)。
  • 硅油填充眼更常合并孔源性脱离(47.0% vs. 21.3%;P<0.0001)和黄斑受累脱离(74.5% vs. 60.0%;P<0.0001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文自述为单中心回顾性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate visual and anatomical outcomes of diabetic tractional retinal detachment repaired with pars plana vitrectomy. METHODS: Operative records were used to retrospectively identify all patients with tractional retinal detachments secondary to proliferative diabetic retinopathy surgically repaired with pars plana vitrectomy between November 1, 2009, and January 1, 2015 at the LAC + USC (Los Angeles County + University of Southern California) Medical Center. RESULTS: A total of 403 eyes with diabetic tractional retinal detachment in 359 patients were included. Successful reattachment of the retina was achieved in 87.6% of eyes after one surgery and 92.6% of eyes at the final follow-up. Best-corrected visual acuity at the final follow-up improved two or more lines in 56.3% of eyes, was stable in 23.8% of eyes, and decreased two or more lines in 19.9% of eyes. Eyes repaired with 23-gauge and 25-gauge vitrectomy systems had similar success rates as eyes treated with 20-gauge instrumentation (P = 0.73). Eyes receiving silicone oil tamponade had lower single-surgery reattachment rates (77.6% vs. 87.6%; P = 0.013), lower reattachment rates at the final follow-up (85.7% vs. 92.6%; P = 0.048), and higher rates of vision loss (34.7% vs. 19.9%; P < 0.0001) but were more likely to have concurrent rhegmatogenous detachment (47.0% vs. 21.3%; P < 0.0001) and macula involving detachment (74.5% vs. 60.0%; P < 0.0001). CONCLUSION: In this large, single-center retrospective study of patients with advanced diabetic tractional retinal detachment, vitrectomy achieved excellent anatomical outcome and improved or stabilized vision in 80.1% of eyes. Smaller gauge vitrectomy systems were found to have similar outcomes to 20-gauge instrumentation.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Storey PP, Ter-Zakarian A, Philander SA, et al. VISUAL AND ANATOMICAL OUTCOMES AFTER DIABETIC TRACTION AND TRACTION-RHEGMATOGENOUS RETINAL DETACHMENT REPAIR. Retina. 2018. PMID: 28796149. doi:10.1097/IAE.0000000000001793

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。