文献速递眼底病与葡萄膜炎

病理性近视后巩膜葡萄肿的广角光学相干断层扫描成像

Posterior Staphylomas in Pathologic Myopia Imaged by Widefield Optical Coherence Tomography.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

本研究对57例高度近视患者(100眼)行广角光学相干断层扫描(WF-OCT),并与三维磁共振成像(3D-MRI)对比后巩膜葡萄肿的检出与分类。结果显示WF-OCT可显示除2个极大葡萄肿外的全部3D-MRI检出葡萄肿,两种技术检出率无显著差异(P=0.12),分类一致性良好(kappa=0.61)。作者认为WF-OCT可能替代3D-MRI评估后巩膜葡萄肿。

要点

  • WF-OCT可显示3D-MRI检出的后巩膜葡萄肿,仅2个极大葡萄肿未被显示。
  • WF-OCT与3D-MRI对葡萄肿检出率无显著差异(P=0.12)。
  • 两种技术对葡萄肿分类一致性良好(kappa=0.61,95%CI 0.50-0.72)。

核心结论

  • WF-OCT可提供迄今无法达到的分辨率和尺寸的后巩膜葡萄肿断层图像。
  • WF-OCT可能替代3D-MRI评估后巩膜葡萄肿。
  • 未来使用WF-OCT的研究可能探索后巩膜葡萄肿的详细形态特征并为病因提供线索。

研究设计与样本

  • 研究纳入高度近视患者(近视屈光度>8.0 D或眼轴长度>26.5 mm)且既往接受过眼眶3D-MRI检查,随后行WF-OCT检查。
  • 共纳入57例患者100眼,平均年龄67.9±10.7岁(范围44-85岁),平均眼轴长度30.0±2.3 mm(范围25.1-36.5 mm)。

主要发现

  • 3D-MRI检出的所有后巩膜葡萄肿中,除2个极大葡萄肿外,均在WF-OCT图像上显示。
  • 后巩膜葡萄肿的形态学特征为葡萄肿边界平滑、脉络膜逐渐变薄及葡萄肿边缘巩膜向内突出。
  • WF-OCT与3D-MRI对葡萄肿检出率比较无显著差异(P=0.12;χ2检验)。
  • 两种技术对葡萄肿分类的一致性良好,一致性指数kappa为0.61(95%置信区间:0.50-0.72)。
  • WF-OCT可观察到葡萄肿区域与黄斑及视神经乳头之间的空间关系。

临床怎么用

  • 作者认为WF-OCT可能替代3D-MRI评估后巩膜葡萄肿。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To examine posterior staphylomas by widefield optical coherence tomography (WF-OCT) and three-dimensional magnetic resonance imaging (3D-MRI). METHODS: Highly myopic patients (myopic refractive error >8.0 diopters or axial length >26.5 mm) who had previously undergone orbital 3D-MRI were examined by WF-OCT. RESULTS: The study included 100 eyes of 57 patients with a mean age of 67.9 ± 10.7 years (range, 44-85 years) and mean axial length of 30.0 ± 2.3 mm (range, 25.1-36.5 mm). All staphylomas detected on the 3D-MRI, except for two very large staphylomas, were visualized on the WF-OCT images. Morphologic hallmarks of the staphylomas were smoothly configured staphyloma border with a gradual thinning of the choroid and an inward protrusion of the sclera at the staphyloma edge. Comparing the detectability of the staphylomas on the WF-OCT images versus 3D-MRI revealed no significant difference between both techniques (P = 0.12; χ2 test). Comparing the staphyloma classification between both techniques showed a good concordance with a concordance index kappa of 0.61 (95% confidence interval: 0.50-0.72). A spatial relationship between the staphylomatous areas and the macula and optic nerve head was observed by WF-OCT. CONCLUSIONS: WF-OCT can provide tomographic images of posterior staphylomas in a resolution and size unachievable so far, and may replace 3D-MRI in assessing posterior staphylomas. Future studies using WF-OCT may explore the detailed morphologic characteristics of posterior staphylomas and give clues to the etiology of staphylomas.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Shinohara K, Shimada N, Moriyama M, et al. Posterior Staphylomas in Pathologic Myopia Imaged by Widefield Optical Coherence Tomography. Invest Ophthalmol Vis Sci. 2017. PMID: 28738419. doi:10.1167/iovs.17-22319

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。