文献速递白内障与屈光手术角膜与眼表疾病

高度近视患者植入散光型与非散光型可植入式胶透镜V4c后前节光学相干断层扫描房角与拱高分析

Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia.
PubMed 文献 · Br J Ophthalmol · 2017-07-20

前瞻性纵向病例系列纳入42例(76眼)高度近视(>6屈光度)患者,行散光型与非散光型ICL V4c植入,术前及术后1周、1、6、12个月在不同光照条件下行光学相干断层扫描。术后1周所有光照条件下虹膜角膜角均显著减小,暗视条件下降14.1°、明视下降14.8°、暗视下降13.2°;随访1年内仅中间视觉条件下房角变化有统计学意义(p=0.01),拱高变化亦有统计学意义(p=0.01)。

要点

  • 术后1周中间视觉、暗视觉和明视觉下虹膜角膜角均显著减小(p<0.05)。
  • 1年随访中仅中间视觉下虹膜角膜角变化有统计学意义(p=0.01)。
  • 中间视觉下术后1周平均拱高为0.661±0.21 mm,1年内变化有统计学意义(p=0.01)。

主要发现

  • 术后1周与术前相比,中间视觉、暗视觉和明视觉下平均虹膜角膜角均显著减小(p<0.05),中间视觉减小14.1°、明视觉减小14.8°、暗视觉减小13.2°。
  • 1年随访中,虹膜角膜角测量仅在中间视觉条件下变化有统计学意义(p=0.01)。
  • 中间视觉下术后1周平均拱高为0.661±0.21 mm,1年随访中中间视觉下拱高变化有统计学意义(p=0.01)。
  • 屈光结果显示裸眼与矫正远视力均显著改善(p<0.001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess anterior segment changes, including iridocorneal angle and vault, after toric and non-toric implantable collamer lens (ICL) V4c (STAAR Surgical AG) implantation under different lighting conditions. METHODS: Longitudinal, prospective, case series. Patients with high myopia (>6 dioptres) underwent toric and non-toric ICL V4c implantation. Optical coherence tomography measurements were taken under different lighting conditions preoperatively and at 1 week and 1, 6 and 12 months of follow-up. RESULTS: Seventy-six eyes of 42 patients underwent ICL V4c implantation. Mean age was 27.4 years (±5.14 years, range 20 to 39 years). The average iridocorneal angle showed a statistically significant decrease (p<0.05) in all mesopic, scotopic and photopic conditions after 1 week of surgery compared with the preoperative measurements; in mesopic conditions, it decreased 14.1°, in photopic conditions 14.8° and scotopic conditions 13.2°. The angle measurement had a statistically significant change only in mesopic conditions (p=0.01) over the 1-year follow-up. The average vault under mesopic conditions was 0.661±0.21 mm at week 1. The vault measurement change was statistically significant over the 1-year follow-up in mesopic conditions (p=0.01). Refractive results showed a significant improvement in both uncorrected and corrected distance visual acuity (p<0.001). CONCLUSION: There is a significant reduction in the iridocorneal angle after ICL V4c implantation. Furthermore, there is a change under mesopic conditions in both the iridocorneal angle and vault during long-term follow-up.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Garcia-De la Rosa G, Olivo-Payne A, Serna-Ojeda JC, et al. Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia. Br J Ophthalmol. 2017. PMID: 28729370. doi:10.1136/bjophthalmol-2017-310518

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。