文献速递角膜与眼表疾病

比较角膜后弹力层剥除自动内皮角膜移植术与穿透性角膜移植术的长期视力结局

Long-term Visual Outcomes Comparing Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty.
PubMed 文献 · Am J Ophthalmol · 2017-07-21

该前瞻性干预性病例系列分析了新加坡角膜移植登记处1991至2011年间828例(DSAEK 423例、PK 405例)因FED或BK行DSAEK或PK的亚洲眼,比较5年视力与屈光结局。DSAEK在5年内BSCVA显著优于PK且SE和散光更低;DSAEK在FED中优势持续5年,在BK中仅持续3年。

要点

  • DSAEK眼5年内BSCVA显著优于PK(P < .001-.037),SE和柱镜更低。
  • DSAEK在FED中优势持续5年(P < .001-.026),在BK中仅持续3年(P < .001-.031)。
  • DSAEK术前BSCVA < 1.3 logMAR者视力结局显著优于≥ 1.3 logMAR者(P < .001-.042)。

核心结论

  • 在本研究队列中,DSAEK在5年随访期内提供的长期BSCVA显著优于PK且散光更低。
  • DSAEK治疗FED的视力结局优于治疗BK。
  • 在1-3年的部分分析中,协方差分析校正提示DSAEK相关的更好长期BSCVA独立于DSAEK眼更好的术前视力。

研究设计与样本

  • 前瞻性干预性病例系列,分析新加坡角膜移植登记处1991至2011年间连续828例因FED和BK行DSAEK(423例)或PK(405例)的病例。
  • 主要结局指标为5年随访期间的最佳眼镜矫正视力(BSCVA)、散光(柱镜)和球镜等效(SE)。

主要发现

  • 平均年龄67.5 ± 11.5岁(男性50.1%,女性49.9%),多种族亚洲人群中以华人为主(76.6%,n = 634)。
  • DSAEK眼5年内BSCVA显著优于PK(P < .001-.037),且SE更低(P < .001-.017)、柱镜更低(P < .001),不依赖于手术指征。
  • DSAEK在FED中5年内优于PK(P < .001-.026),但在BK中仅3年内优于PK(P < .001-.031)。
  • FED眼行DSAEK的BSCVA在4年随访时显著优于BK眼(P = .006)。
  • DSAEK术前BSCVA < 1.3 logMAR者视力结局显著优于≥ 1.3 logMAR者(P < .001-.042)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare 5-year visual acuity and refraction outcome in Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) for Fuchs endothelial dystrophy (FED) or bullous keratopathy (BK) in Asian eyes. DESIGN: Prospective interventional case series. METHODS: We analyzed 828 consecutive cases of DSAEK (423) or PK (405) for FED and BK from the Singapore Cornea Transplant Registry performed from 1991 to 2011. Our main outcome measures were best spectacle-corrected visual acuity (BSCVA) with astigmatism (cylinder) and spherical equivalent (SE) over 5 years of follow-up. RESULTS: Mean age was 67.5 ± 11.5 years (50.1% male, 49.9% female) and majority was Chinese (76.6%, n = 634) in our multiracial Asian population. DSAEK eyes had significantly better BSCVA (P < .001-.037) with lower SE (P < .001-.017) and cylinder (P < .001), independent of surgical indication, compared to PK over 5 years. DSAEK was superior to PK over 5 years (P < .001-.026) in FED, but only over 3 years in BK (P < .001-.031). DSAEK in FED eyes had significantly better BSCVA compared to BK eyes (P = .006 at 4-year follow-up). DSAEKs with preoperative BSCVA < 1.3 logMAR had significantly better visual outcomes than cases with ≥ 1.3 logMAR (P < .001-.042). PKs had significantly higher postoperative refractive correction than DSAEKs, with no significant influence of the surgery indication. CONCLUSIONS: In our study cohort, DSAEK provided significantly better long-term BSCVA and lower astigmatism than PK over 5 years of follow-up. Visual outcomes of DSAEK for FED were better than BK. In some analyses for years 1-3, analysis of covariance adjustment indicated that this DSAEK-associated better long-term BSCVA was independent of better preoperative vision in DSAEK eyes.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Fuest M, Ang M, Htoon HM, et al. Long-term Visual Outcomes Comparing Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty. Am J Ophthalmol. 2017. PMID: 28739420. doi:10.1016/j.ajo.2017.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。