解读10-2视野结果时应考虑视盘与颞侧缝位置个体差异
研究对22眼正常视力志愿者用OCT获取视网膜神经纤维层正面图像,与10-2视野测试点叠加分析。平均视盘-黄斑-颞侧缝角为169.4°±3.2°,视盘和颞侧缝均位于水平中线之上;54.5%眼水平中线旁颞下测试点对应解剖下半球,22.7%眼鼻下测试点对应解剖下半球,与通常假设相反。结论认为10-2视野结构功能映射需考虑颞侧缝位置个体差异。
要点
- 平均视盘-黄斑-颞侧缝角为169.4°±3.2°。
- 54.5%眼水平中线旁颞下10-2测试点对应解剖下半球。
- 22.7%眼水平中线旁鼻下10-2测试点对应解剖下半球,与通常假设相反。
核心结论
- 视盘和颞侧缝的位置影响上下半球间的结构功能映射,10-2测试模式映射时应考虑颞侧缝位置的个体差异。
研究设计与样本
- 对22眼正常视力志愿者(球镜等效+0.75 D至7.88 D)行OCT容积扫描,获取内界膜拟合平面的正面图像。
- 选取最清晰视网膜神经纤维图像,以血管对齐叠加于眼底照片。
- 用视盘、黄斑和视野盲点等个体标志将Humphrey Field Analyzer 10-2视野叠加于OCT图像,与视网膜神经纤维图像比较。
主要发现
- 平均视盘-黄斑-颞侧缝角为169.4°±3.2°。
- 视盘和颞侧缝均位于水平中线之上,即视野空间的下方。
- 54.5%眼水平中线旁颞下10-2测试点对应解剖下半球。
- 22.7%眼水平中线旁鼻下10-2测试点对应解剖下半球,与通常假设相反。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To clarify the anatomical relation between the optic disc and temporal raphe and to examine how these are related to test points in the 10-2 visual field test pattern. SUBJECTS AND METHODS: For 22 eyes of volunteers with normal vision (+0.75 D spherical equivalent 7.88 D), a volume scan was used to obtain en-face images from a plane fitted to the inner limiting membrane using optical coherence tomography (OCT). The clearest en-face retinal nerve fibre (RNF) image was chosen for each subject and superimposed on fundus photographs using blood vessels for alignment. Individual landmarks (disc, fovea and visual field blind spot) were then used to superimpose the Humphrey Field Analyzer 10-2 visual field on the OCT image to compare with the RNF image. RESULTS: The average disc-fovea-raphe angle was 169.4°±3.2°. Both the disc and temporal raphe were located above the horizontal midline (ie, were inferior in visual field space). For the 10-2 test pattern superimposed on the OCT image, in 54.5% of eyes, the temporal inferior test points adjacent to the horizontal midline mapped to the anatomical inferior hemifield. In 22.7% of eyes, nasal inferior test points adjacent to the horizontal midline mapped to the anatomical inferior hemifield. This mapping is opposite to typically assumed. CONCLUSION: The position of the disc and raphe affects the mapping between structure and function with respect to superior and inferior hemifields. Individual differences in the position of the temporal raphe should be considered when mapping between structure and function for the 10-2 test pattern.
引用
- Tanabe F, Matsumoto C, McKendrick AM, et al. The interpretation of results of 10-2 visual fields should consider individual variability in the position of the optic disc and temporal raphe. Br J Ophthalmol. 2017. PMID: 28689167. doi:10.1136/bjophthalmol-2016-309669
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。