文献速递青光眼眼底病与葡萄膜炎

正常眼与青光眼眼视盘及黄斑血管密度OCTA测量的重复性比较

Repeatability of vessel density measurements of optical coherence tomography angiography in normal and glaucoma eyes.
PubMed 文献 · Br J Ophthalmol · 2017-07-24

横断面研究比较正常眼与青光眼眼视盘周围及黄斑OCTA血管密度测量的组内重复性,并评估信号强度指数(SSI)的影响。视盘周围与黄斑测量的重复性在两组间多数相似,但SSI升高与血管密度值显著增加相关(系数0.15至0.38,均p<0.01)。

要点

  • 正常眼与青光眼眼的视盘周围及黄斑OCTA血管密度测量重复性估计多数相似。
  • 重复扫描的SSI升高与视盘周围及黄斑血管密度值显著增加相关(系数0.15至0.38,均p<0.01)。

核心结论

  • 正常眼与青光眼眼的OCTA视盘周围及黄斑血管密度重复性估计相似,SSI对重复性有显著影响,SSI较高的扫描血管密度值增加。

研究设计与样本

  • 横断面研究,纳入65眼(30正常眼、35青光眼眼)各进行3次视盘扫描,69眼(35正常眼、34青光眼眼)各进行3次黄斑扫描,均在同一次检查中完成。
  • 重复性采用个体内重复性系数(CRw)和变异系数(CVw)评估,SSI的影响采用重复测量混合效应模型分析。

主要发现

  • 正常眼视盘周围测量的CRw(%)和CVw(%)范围分别为3.3至7.0和2.5至4.4,青光眼眼分别为3.5至7.1和2.6至6.6。
  • 正常眼黄斑测量的CRw(%)和CVw(%)范围分别为4.1至6.0和3.3至4.7,青光眼眼分别为4.3至6.9和3.7至5.6。
  • 多数测量的重复性估计在正常眼与青光眼眼之间相似。
  • 视盘周围及黄斑血管密度均随重复扫描的SSI增加而显著增加(系数范围0.15至0.38,所有关联p<0.01)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To compare the intrasession repeatability of peripapillary and macular vessel density measurements of optical coherence tomography angiography (OCTA) in normal and glaucoma eyes, and to evaluate the effect of signal strength of OCTA scans on the repeatability. METHODS: In a cross-sectional study, three optic nerve head scans each of 65 eyes (30 normal, 35 glaucoma eyes) and three macular scans each of 69 eyes (35 normal, 34 glaucoma eyes) acquired in the same session with OCTA were analysed. Repeatability was assessed using within-subject coefficient of repeatability (CRw) and variation (CVw). Effect of signal strength index (SSI) on repeatability was evaluated with repeated-measures mixed-effects models. RESULTS: CRw (%) and CVw (%) of peripapillary measurements in normal eyes ranged between 3.3 and 7.0, and 2.5 and 4.4 respectively, and that in glaucoma eyes between 3.5 and 7.1, and 2.6 and 6.6. For the macular, these measurements ranged between 4.1 and 6.0, and 3.3 and 4.7 in normal eyes and 4.3 and 6.9, and 3.7 and 5.6 in glaucoma eyes. Repeatability estimates of most measurements were similar in normal and glaucoma eyes. Vessel densities of both peripapillary and macular regions significantly increased with increase in SSI of repeat scans (coefficients ranging from 0.15 to 0.38, p<0.01 for all associations). CONCLUSIONS: Repeatability estimates of OCTA measured peripapillary and macular vessel densities were similar in normal eyes and eyes with glaucoma. SSI values of the scans had a significant effect on the repeatability of OCTA with the vessel density values increasing in scans with higher SSI values.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Venugopal JP, Rao HL, Weinreb RN, et al. Repeatability of vessel density measurements of optical coherence tomography angiography in normal and glaucoma eyes. Br J Ophthalmol. 2017. PMID: 28739645. doi:10.1136/bjophthalmol-2017-310637

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。