文献速递青光眼眼底病与葡萄膜炎

投影分辨光学相干断层扫描血管成像检测青光眼黄斑视网膜循环

Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma.
PubMed 文献 · Ophthalmology · 2017-07-01

前瞻性观察研究纳入30例视野缺损青光眼和30例年龄匹配正常对照,采用投影分辨光学相干断层扫描血管成像(PR-OCTA)测量黄斑血管密度。青光眼组浅层血管复合体(SVC)和全丛视网膜血管密度低于正常组(均P < 0.001),SVC血管密度诊断准确性最高,校正较差的半球后受试者工作特征曲线下面积(AROC)达0.983,特异性95%时敏感性96.7%。

要点

  • 青光眼组SVC和全丛视网膜血管密度低于正常组(均P < 0.001)。
  • SVC血管密度诊断青光眼准确性最高,校正较差半球后AROC 0.983。
  • 反射补偿显著改善血管密度测量的重复性和与视野、GCC厚度的相关性。

核心结论

  • 基于PR-OCTA,青光眼对黄斑SVC灌注的影响大于深层丛。
  • 反射补偿的SVC血管密度测量以高准确性检测青光眼,可能有助于青光眼临床评估。

研究设计与样本

  • 前瞻性观察研究,纳入30例视野缺损青光眼和30例年龄匹配正常参与者,每例取一眼行6×6-mm黄斑OCTA扫描。

主要发现

  • 青光眼眼SVC可见局灶毛细血管无灌注,而ICP和DVP未见。
  • 青光眼组SVC和全丛视网膜血管密度(均值±标准差:47.2%±7.1%和73.5%±6.6%)低于正常组(60.5%±4.0%和83.2%±4.2%,均P < 0.001,t检验)。
  • 青光眼组ICP和DCP血管密度未显著低于正常组。
  • 在校正较差的半球(下或上)后,SVC血管密度诊断准确性更优,AROC 0.983,特异性95%时敏感性96.7%。
  • 在青光眼参与者中,半球SVC血管密度值与相应GCC厚度和视野敏感性高度相关(P < 0.003)。

关键数值与推荐

  • 总体黄斑血管密度参数中,SVC血管密度诊断准确性最佳(以AROC衡量)。
  • 反射补偿步骤显著改善重复性、正常人群变异以及与视野和GCC厚度的相关性。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To detect macular perfusion defects in glaucoma using projection-resolved optical coherence tomography (OCT) angiography. DESIGN: Prospective observation study. PARTICIPANTS: A total of 30 perimetric glaucoma and 30 age-matched normal participants were included. METHODS: One eye of each participant was imaged using 6×6-mm macular OCT angiography (OCTA) scan pattern by 70-kHz 840-nm spectral-domain OCT. Flow signal was calculated by the split-spectrum amplitude-decorrelation angiography algorithm. A projection-resolved OCTA (PR-OCTA) algorithm was used to remove flow projection artifacts. Four en face OCTA slabs were analyzed: the superficial vascular complex (SVC), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and all-plexus retina (SVC + ICP + DCP). The vessel density (VD), defined as the percentage area occupied by flow pixels, was calculated from en face OCTA. A novel algorithm was used to adjust the vessel density to compensate for local variations in OCT signal strength. MAIN OUTCOME MEASURES: Macular retinal VD, ganglion cell complex (GCC) thickness, and visual field (VF) sensitivity. RESULTS: Focal capillary dropout could be visualized in the SVC, but not the ICP and DVP, in glaucomatous eyes. In the glaucoma group, the SVC and all-plexus retinal VD (mean ± standard deviation: 47.2%±7.1% and 73.5%±6.6%) were lower than in the normal group (60.5%±4.0% and 83.2%±4.2%, both P < 0.001, t test). The ICP and DCP VD were not significantly lower in the glaucoma group. Among the overall macular VD parameters, the SVC VD had the best diagnostic accuracy as measured by the area under the receiver operating characteristic curve (AROC). The accuracy was even better when the worse hemisphere (inferior or superior) was used, achieving an AROC of 0.983 and a sensitivity of 96.7% at a specificity of 95%. Among the glaucoma participants, the hemispheric SVC VD values were highly correlated with the corresponding GCC thickness and VF sensitivity (P < 0.003). The reflectance compensation step in VD calculation significantly improved repeatability, normal population variation, and correlation with VF and GCC thickness. CONCLUSIONS: On the basis of PR-OCTA, glaucoma preferentially affects perfusion in the SVC in the macula more than the deeper plexuses. Reflectance-compensated SVC VD measurement by PR-OCTA detected glaucoma with high accuracy and could be useful in the clinical evaluation of glaucoma.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Takusagawa HL, Liu L, Ma KN, et al. Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma. Ophthalmology. 2017. PMID: 28676279. doi:10.1016/j.ophtha.2017.06.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。