Stargardt病与RPGR相关视网膜病变患者视锥细胞密度测量的可靠性与可重复性
本研究评估共焦与非共焦分裂检测自适应光学扫描光检眼镜(AOSLO)在Stargardt病(STGD)和RPGR相关视网膜病变中测量视锥细胞密度的可靠性与可重复性。纳入12例STGD患者(9-52岁)和8例RPGR相关视网膜病变患者(11-31岁),同时使用两种模式成像并由4名分级者手动识别视锥细胞位置。结果显示分裂检测AOSLO大幅提高两种疾病的可靠性与可重复性,但指数可能具有疾病依赖性。
要点
- 分裂检测AOSLO在STGD中可靠性95.9%、可重复性97.3%,均高于共焦模式的67.9%和71.2%。
- 分裂检测AOSLO在RPGR相关视网膜病变中可靠性88.5%、可重复性94.5%,均高于共焦模式的22.1%和63.2%。
- 两种模式间视锥细胞密度差异:STGD中仅1名分级者达统计学显著,RPGR中所有分级者均达统计学显著。
核心结论
- 分裂检测AOSLO大幅提高了两种疾病中视锥细胞密度测量的可靠性与可重复性,将有助于使用AOSLO的自然病史研究和临床试验。
- 这些指数可能具有疾病依赖性,意味着需要在其他疾病中开展类似研究。
研究设计与样本
- 纳入12例Stargardt病(STGD)患者(年龄9-52岁)和8例RPGR相关视网膜病变患者(年龄11-31岁),同时使用共焦和分裂检测AOSLO成像。
- 4名分级者手动识别每张图像中的视锥细胞位置以计算局部密度,每种成像模式独立评估。
- 数据集包括99张STGD图像的1584次评估(每张图像两种模式,4名分级者各分级两次)和58张RPGR图像的928次评估(每张图像两种模式,4名分级者各分级两次)。
主要发现
- STGD评估中,共焦和分裂检测AOSLO的可靠性分别为67.9%和95.9%,可重复性分别为71.2%和97.3%。
- STGD中两种模式间测量的视锥细胞密度差异对1名分级者达统计学显著。
- RPGR评估中,共焦和分裂检测AOSLO的可靠性分别为22.1%和88.5%,可重复性分别为63.2%和94.5%。
- RPGR中两种模式间视锥细胞密度差异对所有分级者均达统计学显著。
关键数值与推荐
- STGD中分裂检测AOSLO可靠性95.9%、可重复性97.3%,共焦模式可靠性67.9%、可重复性71.2%。
- RPGR相关视网膜病变中分裂检测AOSLO可靠性88.5%、可重复性94.5%,共焦模式可靠性22.1%、可重复性63.2%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文指出这些指数可能具有疾病依赖性,意味着需要在其他疾病中开展类似研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)-associated retinopathy. METHODS: Twelve patients with STGD (aged 9-52 years) and eight with RPGR-associated retinopathy (aged 11-31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). RESULTS: For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. CONCLUSIONS: Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions.
引用
- Tanna P, Kasilian M, Strauss R, et al. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy. Invest Ophthalmol Vis Sci. 2017. PMID: 28738413. doi:10.1167/iovs.17-21904
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。