标准化非对称软性接触镜在圆锥角膜患者中的视觉表现与光学质量
研究纳入30眼(26例)圆锥角膜患者(平均K值45.7±2.3 D),评估标准化非对称软性接触镜矫正高阶像差的视觉效果。配戴后最佳眼镜矫正视力从-0.07±0.09 logMAR改善至-0.11±0.08 logMAR(P<0.05),视觉模拟评分从66.2±21.8提高至75.4±20.5(P<0.05),垂直彗差显著降低。
要点
- 标准化非对称软性接触镜可降低圆锥角膜患者高阶像差并改善视觉质量。
- 最佳眼镜矫正视力从-0.07±0.09改善至-0.11±0.08 logMAR(P<0.05)。
- 垂直彗差从无镜片时-0.50±0.36 μm降至戴镜时-0.36±0.34 μm(P<0.01)。
核心结论
- 与框架眼镜相比,标准化非对称软性接触镜可降低配戴硬性透气性接触镜的圆锥角膜患者的高阶像差并改善视觉质量。
研究设计与样本
- 研究纳入30眼(26例)圆锥角膜患者,平均K值45.7±2.3 D,患者接受角膜断层扫描、像差测量、显然验光和视力及视觉模拟评分评估。
- 研究镜片采用模压法制成,包含六种标准化类型,采用约2至12 D(2 D步进)的非对称屈光力分布矫正高阶像差。
- 根据角膜断层扫描和像差测量数据为每只眼选择合适镜片类型,并通过像差测量(4 mm瞳孔)、过矫验光、视力和视觉模拟评分评估镜片在眼表现。
主要发现
- 标准化非对称软性接触镜使最佳眼镜矫正视力从-0.07±0.09 logMAR改善至-0.11±0.08 logMAR(P<0.05)。
- 平均视觉模拟评分从66.2±21.8提高至75.4±20.5(P<0.05)。
- 垂直彗差从无镜片时-0.50±0.36 μm降至戴镜时-0.36±0.34 μm(P<0.01)。
- 亚组分析中,高视觉模拟评分组(评分≥75)占全部受试者的70%,该组垂直彗差较无镜片时显著降低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the visual performance and optical quality of a standardized asymmetric soft contact lens (SCL) used for correction of higher-order aberrations (HOAs) in eyes with keratoconus. METHODS: We included 30 eyes (26 patients) with keratoconus (average K: 45.7 ± 2.3 diopters [D]). The patients were subjected to corneal tomography, aberrometry, measurements of manifest refraction and visual acuity (VA), and visual analog scale (VAS) assessments. The study lenses were made using a molding method and consisted of six standardized types, in which an asymmetric power distribution of approximately 2 to 12 D (2-D step) was used to correct HOAs. The lens type suitable for each eye was selected based on the corneal tomography and aberrometry data. The on-eye performance of the lens was evaluated using aberrometry (4-mm pupil), over refraction, VA, and VAS. RESULTS: The standardized asymmetric SCL improved the best spectacle-corrected VA from -0.07 ± 0.09 to -0.11 ± 0.08 logMAR (P < 0.05) and the mean VAS score from 66.2 ± 21.8 to 75.4 ± 20.5 (P < 0.05). Vertical coma decreased significantly (-0.50 ± 0.36 μm without SCL; -0.36 ± 0.34 μm with SCL; P < 0.01). In subgroup analysis, subjects in the high VAS group (score ≥ 75) accounted for 70% of all subjects, and this was the group in which the vertical coma decreased significantly from the level without the lens. CONCLUSIONS: A standardized asymmetric SCL can reduce HOAs and improve vision quality when compared with spectacles in patients with keratoconus who wear rigid gas-permeable lenses.
引用
- Suzaki A, Maeda N, Fuchihata M, et al. Visual Performance and Optical Quality of Standardized Asymmetric Soft Contact Lenses in Patients With Keratoconus. Invest Ophthalmol Vis Sci. 2017. PMID: 28586914. doi:10.1167/iovs.16-21296
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。