使用Scheimpflug成像比较圆锥角膜的角膜动态参数与断层扫描测量

Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus.
PubMed 文献 · Br J Ophthalmol · 2017-05-30

本研究纳入42眼(圆锥角膜II-III级21眼、年龄匹配正常21眼),用Pentacam和Corvis测量,通过ROC曲线比较诊断能力。BAD最终D值AUC最高(0.994),Corvis参数中DA ratio 2的AUC为0.946且pAUC最高(0.177);BAD与DA ratio 1(p≥0.162)、DA ratio 2(p≥0.208)的AUC和pAUC无显著差异。作者认为Corvis测量有潜力区分圆锥角膜与正常眼,新参数诊断能力与Pentacam相当。

要点

  • BAD最终D值AUC为0.994、pAUC为0.194,在全部参数中最高。
  • Corvis参数中DA ratio 2的AUC为0.946、pAUC为0.177,表现仅次于BAD。
  • BAD与DA ratio 1(p≥0.162)、DA ratio 2(p≥0.208)的AUC和pAUC无显著差异。

核心结论

  • 作者认为Corvis测量有潜力区分圆锥角膜与正常眼,新参数诊断能力与Pentacam相当。

研究设计与样本

  • 连续纳入II-III级圆锥角膜患者和年龄匹配的正常受试者,使用Pentacam和Corvis进行角膜成像,Corvis软件beta版包含最大弧长变化、形变幅度(DA)ratio 1和DA ratio 2三个附加参数,用ROC曲线评估两种设备区分正常与圆锥角膜眼的能力。
  • 共纳入42眼(42例),其中圆锥角膜21例、正常受试者21例,两组年龄匹配(p=0.760)。

主要发现

  • BAD最终D值的AUC为0.994、pAUC为0.194,均为最高。
  • 最大逆半径的AUC为0.954但pAUC相对较低(0.158);DA ratio 2的AUC为0.946、pAUC为0.177,在Corvis参数中AUC第二高且pAUC最高。
  • BAD与DA ratio 1的AUC和pAUC比较p≥0.162,与DA ratio 2比较p≥0.208,均无显著差异。

关键数值与推荐

  • BAD最终D值:AUC 0.994,pAUC 0.194(特异性≥80%)。
  • 最大逆半径:AUC 0.954,pAUC 0.158(特异性≥80%)。
  • DA ratio 1与BAD比较:AUC和pAUC的p≥0.162;DA ratio 2与BAD比较:p≥0.208。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. METHODS: Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgeräte, Wetzlar, Germany) and Corvis (Oculus Optikgeräte). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity ≥80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. RESULTS: Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p≥0.162) and DA ratio 2 (p≥0.208). CONCLUSIONS: The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。