文献速递青光眼白内障与屈光手术

晶状体混浊对使用解剖定位系统(APS)的SD-OCT视网膜神经纤维层和Bruch膜开口测量的影响

The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

研究纳入59例接受择期白内障手术且无其他相关眼病的患者,使用解剖定位系统(APS)的Spectralis OCT于术前和术后1天测量视网膜神经纤维层厚度、Bruch膜开口面积和Bruch膜开口最小边缘宽度,并用Scheimpflug图像密度测定法量化晶状体混浊。结果显示手术前后各测量值几乎相同,基线视网膜神经纤维层厚度与晶状体混浊无关,作者认为APS可能有助于减少白内障对测量的影响。

要点

  • 白内障手术前后视网膜神经纤维层厚度、Bruch膜开口面积和最小边缘宽度几乎相同。
  • 基线视网膜神经纤维层厚度与晶状体混浊程度无关联。
  • 作者认为APS可能有助于更精确的OCT测量并减少白内障影响。

核心结论

  • 使用APS时,白内障手术后视网膜神经纤维层厚度保持不变,这与既往研究报告的结果相反。
  • 作者认为APS可能有助于更精确的谱域OCT测量,在本队列中最小化了白内障对视网膜神经纤维层厚度和Bruch膜开口评估的影响。

研究设计与样本

  • 研究纳入59例随机选取的、无其他相关眼病并接受择期常规白内障手术的患者,来自两家专业眼科诊所。
  • 使用Heidelberg Engineering Spectralis OCT和解剖定位系统(APS),于白内障手术前和术后1天,采用视盘不同离心率(3.5、4.1和4.7 mm)的环形扫描评估视网膜神经纤维层厚度、Bruch膜开口面积和Bruch膜开口最小边缘宽度。
  • 使用基于Scheimpflug图像(Oculus Pentacam AXL)的密度测定法定量晶状体混浊。

主要发现

  • 视网膜神经纤维层厚度、Bruch膜开口面积和Bruch膜开口最小边缘宽度在白内障摘除前后几乎相同。
  • 该结果在总体评估、3.5 mm扫描的六个扇区以及任何其他离心率评估时均成立。
  • 基线视网膜神经纤维层厚度与晶状体混浊无关联。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. METHODS: Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL). RESULTS: RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity. CONCLUSIONS: Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Mauschitz MM, Roth F, Holz FG, et al. The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS). Invest Ophthalmol Vis Sci. 2017. PMID: 28564701. doi:10.1167/iovs.17-21675

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。