临床显著性人工晶状体眼黄斑囊样水肿中脉络膜厚度的变化
这是一项回顾性观察性临床研究,用增强深度成像频域OCT测量34只临床显著性人工晶状体眼黄斑囊样水肿(PCME)眼的脉络膜厚度。黄斑中心凹下脉络膜厚度在诊断时为258±83 μm,水肿消退后降至215±79 μm(P<0.001);基线时对侧眼为194±77 μm,低于急性PCME眼(P<0.001)及水肿消退后(P=0.011)。作者认为这些发现可能支持PCME存在炎症性发病机制的假说。
要点
- 34只PCME眼黄斑中心凹下脉络膜厚度由基线258±83 μm降至水肿消退后215±79 μm(P<0.001)。
- 基线时对侧眼黄斑中心凹下脉络膜厚度194±77 μm,低于急性PCME眼(P<0.001)及消退后(P=0.011)。
- 作者认为脉络膜厚度在PCME中增厚、消退后变薄,可能支持炎症性发病机制假说。
核心结论
- PCME眼的脉络膜厚度增加,水肿消退后降低;这些发现可能支持PCME存在炎症性发病机制的假说。
研究设计与样本
- 回顾性、观察性临床研究,复习超声乳化手术顺利、术后发生临床显著性PCME的病例记录,共测量34只PCME眼。
- 用增强深度成像频域OCT(Spectralis;Heidelberg Engineering)在PCME诊断时测量双眼脉络膜厚度,并在患眼CME消退后复测。
- 测量位置为黄斑中心凹下及距中心凹1.5 mm的鼻侧、颞侧、下方和上方;统计分析采用配对t检验和Pearson相关分析。
主要发现
- 34只PCME眼黄斑中心凹下脉络膜厚度在基线时为258±83 μm,CME消退后降至215±79 μm(P<0.001)。
- 基线时对侧眼黄斑中心凹下脉络膜厚度为194±77 μm,低于急性PCME眼(P<0.001),也低于CME消退后(P=0.011)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate choroidal thickness in eyes with clinically significant pseudophakic cystoid macular edema (PCME) during the acute phase and following resolution of the edema, using enhanced depth imaging spectral domain optical coherence tomography (EDI-OCT). METHODS: This is a retrospective, observational clinical study. Patients' records were reviewed for cases of clinically significant PCME after uneventful phacoemulsification surgery. Choroidal thickness was measured at time of PCME diagnosis in both eyes and after CME resolution in the affected eye using enhanced depth imaging spectral domain optical coherence tomography (Spectralis; Heidelberg Engineering). Measurements were taken subfoveal and 1.5 mm nasal, temporal, inferior, and superior from the center of the fovea. Statistical analysis was performed using paired t-test and Pearson correlation. RESULTS: Mean subfoveal choroidal thickness in 34 eyes with PCME measured 258 ± 83 μm at baseline and decreased to 215 ± 79 μm after CME resolution (P < 0.001). Mean subfoveal choroidal thickness measured at baseline in fellow eyes was significantly lower (194 ± 77 μm) compared to acute PCME (P < 0.001) and after CME resolution (P = 0.011). CONCLUSION: Choroidal thickness is increased in eyes with PCME and decreases following edema resolution. These findings may strengthen the hypothesis of an inflammatory pathogenesis in PCME.
引用
- Fleissig E, Cohen S, Iglicki M, et al. CHANGES IN CHOROIDAL THICKNESS IN CLINICALLY SIGNIFICANT PSEUDOPHAKIC CYSTOID MACULAR EDEMA. Retina. 2018. PMID: 28654631. doi:10.1097/IAE.0000000000001747
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。