文献速递青光眼角膜与眼表疾病

结膜活体共聚焦显微镜成像作为青光眼滤过手术结局的预测工具

In Vivo Confocal Imaging of the Conjunctiva as a Predictive Tool for the Glaucoma Filtration Surgery Outcome.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

纳入66例接受滤过手术的青光眼患者,术前用活体共聚焦显微镜(IVCM)测量结膜树突状细胞密度(DCD)、杯状细胞密度(GCD)和基质网架反射率(SMR),术后12个月随访。手术成功43例(完全成功25例、条件成功18例),失败23例;术前DCD和SMR较低、GCD较高者手术成功率更高,12个月眼压降幅与术前DCD和SMR负相关、与GCD正相关。

要点

  • 术前结膜DCD和SMR较低、GCD较高的青光眼患者滤过手术成功率更高。
  • 12个月眼压降幅与术前DCD(r=-0.786)和SMR(r=-0.618)负相关,与GCD(r=0.752)正相关。
  • IVCM测量的结膜参数可能与滤过手术结局相关,DCD相关性最强。

核心结论

  • 术前DCD、GCD和SMR是与滤过手术结局相关的参数,其中DCD相关性最强。
  • 结膜IVCM可能作为一种预测青光眼手术成功的成像工具。

研究设计与样本

  • 纳入66例接受滤过手术的青光眼患者,术前在计划手术部位行IVCM检查,术后12个月在滤过泡部位重复检查。
  • 手术成功定义为末次随访时眼压较基线降低三分之一。

主要发现

  • 手术成功43例(完全成功25例、条件成功18例),失败23例。
  • 基线眼压(mm Hg)在完全成功组为27.6±2.8、条件成功组为28.8±4.1、失败组为27.7±3.2。
  • 术前DCD和SMR在完全成功组低于条件成功组(P<0.001,P<0.05)和失败组(P<0.001);术前GCD在完全成功组高于条件成功组和失败组(P<0.001)。
  • DCD和GCD在条件成功组与失败组之间也有差异(P<0.05,P<0.001)。
  • 12个月眼压降幅在完全成功组为43.3%、条件成功组为38.4%、失败组为15.8%。

临床怎么用

  • 作者认为结膜IVCM可能作为一种预测青光眼滤过手术成功的成像工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To examine the preoperative conjunctival dendritic cell density (DCD), goblet cell density (GCD), and stromal meshwork reflectivity (SMR) in glaucomatous patients undergoing filtration surgery, using in vivo confocal microscopy (IVCM). METHODS: Sixty-six patients were enrolled. At baseline, IVCM was performed at the site planned for surgery, and was repeated after 12 months at bleb site. Surgery was successful when a one-third reduction of baseline IOP was obtained at the last follow-up. The main outcomes were baseline DCD, GCD, and SMR, and 12 months IOP. The relations between baseline confocal parameters and 12 months IOP were analyzed. RESULTS: Filtration surgery was successful in 43 patients (group 1: complete success, 25; group 2: qualified success, 18), and unsuccessful in 23 patients (group 3). Baseline IOP (mm Hg) was 27.6 ± 2.8, 28.8 ± 4.1, and 27.7 ± 3.2 in groups 1 to 3, respectively. Preoperative DCD and SMR were lower in group 1 compared with groups 2 (P < 0.001, P < 0.05), and 3 (P < 0.001); preoperative GCD was higher in group 1 compared with groups 2 and 3 (P < 0.001). DCD and GCD were also different between groups 2 and 3 (P < 0.05, P < 0.001). At 12 months, IOP reduced by 43.3%, 38.4%, and 15.8% in groups 1 to 3. Twelve-month IOP reduction negatively correlated with baseline DCD and SMR (P < 0.001, r = -0.786; P < 0.05, r = -0.618), and positively with GCD (P < 0.001, r = 0.752). CONCLUSIONS: Preoperative DCD, GCD, and SMR are parameters correlated with the filtration surgery outcome, with DCD presenting the strongest correlation. IVCM of the conjunctiva may represent an imaging tool to predict the surgical success in glaucoma.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Mastropasqua R, Fasanella V, Brescia L, et al. In Vivo Confocal Imaging of the Conjunctiva as a Predictive Tool for the Glaucoma Filtration Surgery Outcome. Invest Ophthalmol Vis Sci. 2017. PMID: 28586797. doi:10.1167/iovs.17-21795

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。