绿光自发荧光与蓝光自发荧光联合近红外反射成像在年龄相关性黄斑变性继发地图样萎缩中的比较
本研究比较了绿光眼底自发荧光(GAF)与蓝光眼底自发荧光(BAF)联合近红外反射(NIR)或单独BAF在年龄相关性黄斑变性继发地图样萎缩(GA)病灶大小定量中的读者间一致性。结果显示GAF测量值平均大于BAF+NIR和BAF,且GAF的读者间一致性最高(CR 0.196 mm,ICC 0.995),提示GAF可能更适用于以病灶大小变化为临床终点的试验。
要点
- GAF测量GA面积平均比BAF+NIR大0.062 mm,比BAF大0.077 mm。
- 读者间一致性GAF最高(CR 0.196 mm,ICC 0.995),其次BAF+NIR(0.232 mm,0.992)和BAF(0.263 mm,0.991)。
- 屈光介质混浊对BAF边界划定的干扰大于GAF,与读者间差异相关。
核心结论
- 基于共聚焦扫描激光检眼镜的GAF和BAF+NIR联合成像配合半自动病灶勾画可对GA进行准确且可重复的定量。
- GAF略优的读者间一致性提示在以病灶大小变化为临床终点的临床试验中可能更倾向于使用GAF。
研究设计与样本
- 研究纳入29例患者(平均年龄79.7岁)的40只眼,均为年龄相关性黄斑变性继发地图样萎缩。
- 按照标准化方案采集共聚焦扫描激光检眼镜的GAF、BAF和NIR图像。
- 由四名独立读者使用半自动软件(RegionFinder;Heidelberg Engineering,海德堡,德国)分析GAF、BAF联合NIR(BAF+NIR)或单独BAF的GA面积。
- 采用混合效应模型评估成像模态对测量的平方根病灶面积的影响,并评估平方根病灶面积、病灶周长和圆度的可重复性系数(CR)和组内相关系数(ICC)。
主要发现
- GAF测量值平均比BAF+NIR测量值大0.062 mm(95%CI 0.04-0.08 mm),比BAF测量值大0.077 mm(95%CI 0.06-0.10 mm)。
- 读者间一致性GAF最高(CR 0.196 mm,ICC 0.995),其次为BAF+NIR(CR 0.232 mm,ICC 0.992)和单独BAF(CR 0.263 mm,ICC 0.991)。
- 病灶周长和圆度也呈现相同趋势。
- 事后回顾发现读者间差异与屈光介质混浊干扰病灶边界划定有关,且BAF较GAF受影响更大。
关键数值与推荐
- GAF测量GA面积平均比BAF+NIR大0.062 mm(95%CI 0.04-0.08 mm)。
- GAF测量GA面积平均比BAF大0.077 mm(95%CI 0.06-0.10 mm)。
- GAF的读者间一致性:CR 0.196 mm,ICC 0.995。
- BAF+NIR的读者间一致性:CR 0.232 mm,ICC 0.992。
- 单独BAF的读者间一致性:CR 0.263 mm,ICC 0.991。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the intermodality and interreader agreement for geographic atrophy (GA) lesion size quantification in green-light fundus autofluorescence (GAF; excitation = 518 nm) versus combined blue-light fundus autofluorescence (BAF; excitation = 488 nm) and near-infrared reflectance (NIR; 820 nm) -based grading. METHODS: Confocal scanning laser ophthalmoscopy (cSLO) GAF, BAF, and NIR images of 40 eyes from 29 patients (mean age 79.7 years) with GA secondary to AMD were recorded according to a standardized protocol. GA areas were analyzed in GAF, BAF combined with NIR (BAF+NIR), or BAF alone, by four independent readers using semiautomated software (RegionFinder; Heidelberg Engineering, Heidelberg, Germany). A mixed-effects model was used to assess the effect of image modality on the measured square-root lesion area. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were assessed for the square-root lesion area, lesion perimeter, and circularity. RESULTS: GAF-based measurements were on average 0.062 mm (95% confidence interval [CI] 0.04-0.08 mm) larger than BAF+NIR-based measurements and 0.077 mm (95% CI 0.06 - 0.10 mm) larger than BAF-based measurements. Interreader agreement was highest for GAF-based analysis ([CR, ICC] 0.196 mm, 0.995) followed by BAF+NIR (0.232 mm, 0.992) and BAF alone (0.263 mm, 0.991). The same was noted for the lesion perimeter and circularity. Post hoc review revealed that interreader differences were associated with media opacification interfering with lesion boundary demarcation to a larger extent in BAF than in GAF. CONCLUSIONS: cSLO-based GAF and combined BAF+NIR imaging with semiautomated lesion delineation allow for an accurate and reproducible quantification of GA. The slightly better interreader agreement using cSLO GAF suggests that its use may be preferable in clinical trials examining the change in lesion size as a clinical endpoint.
引用
- Pfau M, Goerdt L, Schmitz-Valckenberg S, et al. Green-Light Autofluorescence Versus Combined Blue-Light Autofluorescence and Near-Infrared Reflectance Imaging in Geographic Atrophy Secondary to Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2017. PMID: 28632841. doi:10.1167/iovs.17-21764