文献速递角膜与眼表疾病白内障与屈光手术

白内障术后后弹力层脱离发生率及空气后弹力层固定术疗效的回顾性研究

A retrospective study on the incidence of post-cataract surgery Descemet's membrane detachment and outcome of air descemetopexy.
PubMed 文献 · Br J Ophthalmol · 2017-06-13

该回顾性研究分析了2013年1月至2015年12月在Aravind眼科医院因白内障术后后弹力层脱离(DMD)行空气后弹力层固定术的112例患者记录,发现DMD在囊外白内障摘除术(0.26%)和手法小切口白内障手术(0.11%)中的发生率高于超声乳化(0.04%),首次空气固定术后110例中78例(71%)后弹力层复位,结论认为空气后弹力层固定术安全有效,即使严重DMD也应在行内皮角膜移植等大手术前尝试。

要点

  • DMD发生率:囊外摘除0.26%、手法小切口0.11%、超声乳化0.04%(p=0.005和p<0.0001)。
  • 首次空气后弹力层固定术后71%(78/110)后弹力层复位,持续DMD占21.8%。
  • 解剖复位成功后1个月约75%患者视力优于6/18。

核心结论

  • 空气后弹力层固定术是治疗DMD安全有效的方式,即使严重DMD也应在计划内皮角膜移植等大手术前尝试。

研究设计与样本

  • 回顾性研究,纳入2013年1月至2015年12月在Aravind眼科医院因白内障术后威胁视力的DMD行空气后弹力层固定术的112例患者记录。

主要发现

  • 平均年龄66.47±8.46岁,男女比例45:67。
  • DMD发生率在囊外白内障摘除术为0.26%、手法小切口白内障手术为0.11%,均高于超声乳化的0.04%(p=0.005和p<0.0001)。
  • DMD在手术学员中发生率0.17%高于顾问医师的0.07%(p≤0.0001)。
  • 首次空气后弹力层固定术后110例中78例(71%)后弹力层复位。
  • 后弹力层固定术后并发症包括持续性DMD(21.8%)、角膜失代偿(7.3%)、贴附性房角关闭(18%)、空气致瞳孔阻滞(2.7%)和葡萄膜炎(2.7%)。

临床怎么用

  • 作者结论认为空气后弹力层固定术是DMD安全有效的治疗方式,即使严重DMD也应在计划内皮角膜移植等大手术前尝试。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To study the anatomic and functional outcome of air descemetopexy in postcataract surgery Descemet's membrane detachment (DMD). DESIGN: Retrospective study. METHODS: Setting: Institutional. STUDY POPULATION: Records of 112 patients who underwent air descemetopexy for postcataract surgery sight-threatening DMD at Aravind Eye Hospital, Pondicherry, between January 2013 and December 2015 were studied. MAIN OUTCOME MEASURES: Anatomical outcome refers to reattachment of the Descemet's membrane (DM). Functional outcome was given by the best-corrected visual acuity. RESULTS: The mean age was 66.47±8.46 (SD) years, the male to female ratio was 45:67. The incidence of DMD was more in extracapsular cataract extraction (0.26%) and manual small incision cataract surgery (0.11%) than phacoemulsification (0.04%) (p=0.005 and p<0.0001). DMD was more common among surgical trainees (0.17%) than consultants (0.07%) (p≤0.0001). After primary air descemetopexy, 78 (71%) out of the 110 patients had DM reattachment. The complications noted after descemetopexy include persistent DMD (21.8%), corneal decompensation (7.3%), appositional angle closure (18%), pupillary block with air (2.7%) and uveitis (2.7%). Age, sex and timing of intervention did not influence the reattachment rate. Fifteen patients underwent repeat air descemetopexy for persistent DMD among whom nine (60%) had successful reattachment. Almost 75% of patients had vision better than 6/18 1 month after anatomically successful descemetopexy. CONCLUSION: Air descemetopexy is a safe and efficient modality of treatment of DMD and should be tried even in patients with severe DMD before planning a major surgery like endothelial keratoplasty.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Odayappan A, Shivananda N, Ramakrishnan S, et al. A retrospective study on the incidence of post-cataract surgery Descemet's membrane detachment and outcome of air descemetopexy. Br J Ophthalmol. 2017. PMID: 28611131. doi:10.1136/bjophthalmol-2016-309766

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。