文献速递角膜与眼表疾病

圆锥角膜周边与中央基质超微结构研究

Ultrastructural study of peripheral and central stroma of keratoconus cornea.
PubMed 文献 · Br J Ophthalmol · 2017-04-17

研究比较5例正常角膜与3例圆锥角膜的周边和中央基质板层组织,电镜观察显示圆锥角膜中央与周边基质板层紊乱、后基质波动更重,周边中后基质板层厚度显著薄于中央对应区,且圆锥角膜周边与中央板层均显著薄于正常角膜对应区。结论提示周边基质板层参与圆锥角膜致病,波动可能起自后弹力层。

要点

  • 圆锥角膜中央与周边基质板层紊乱,后基质波动更明显。
  • 圆锥角膜周边中基质1030.32±86.25 nm、后基质615.68±30.94 nm,薄于中央对应区1151.1±48 nm、783.57±31.10 nm(p<0.05)。
  • 圆锥角膜周边与中央板层均显著薄于正常角膜对应区(p<0.0001)。

核心结论

  • 研究显示板层参与圆锥角膜周边基质的致病过程,后弹力层附近出现的小波动提示波动可能起自后弹力层。

研究设计与样本

  • 对5例正常角膜与3例圆锥角膜以2.5%戊二醛固定、电镜制片,用JEOL 1400透射电镜观察,以iTEM软件测量板层,SPSS软件作统计分析。

主要发现

  • 圆锥角膜中央与周边基质板层组织被多处波动打乱,后基质波动更重。
  • 圆锥角膜周边中基质板层平均厚度1030.32±86.25 nm、后基质615.68±30.94 nm,显著薄于中央对应区1151.1±48 nm、783.57±31.10 nm(p<0.05)。
  • 圆锥角膜周边后弹力层正上方可见小波动似从后弹力层发出,周边前基质含多处板层缝。
  • 圆锥角膜周边与中央板层平均厚度均显著薄于正常角膜对应区(p<0.0001)。

关键数值与推荐

  • 圆锥角膜周边中基质板层厚度1030.32±86.25 nm vs 中央1151.1±48 nm(p<0.05)。
  • 圆锥角膜周边后基质板层厚度615.68±30.94 nm vs 中央783.57±31.10 nm(p<0.05)。
  • 圆锥角膜周边与中央板层厚度均薄于正常角膜对应区(p<0.0001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Assess the lamellar organisation of the peripheral and central stroma of the keratoconus (KC) and normal cornea. METHODS: Five normal and three KC corneas were fixed in 2.5% glutaraldehyde and processed for electron microscopy. The ultrathin sections were observed under JEOL 1400 TEM, and digital images were taken with a bottom-mounted 11-megapixel Quamisa camera, using the iTEM software. Measurements of the lamellae were carried out using the iTEM software. Statistical analysis was performed using the SPSS software. RESULTS: The lamellar organisation at the centre and periphery of the KC cornea was disrupted by the presence of multiple undulations, which were more aggressive at the posterior stroma. Among the KC cornea, the mean lamellar thickness of the peripheral middle (1030.32±86.25 nm) and posterior (615.68±30.94 nm) stroma was also significantly (p<0.05) thinner than their corresponding areas of the central KC cornea (1151.1±48 nm; 783.57±31.10 nm). At the periphery of KC cornea, just above the Descemet's membrane (DM), small undulations appeared to emerge out from the DM. Furthermore, the anterior stroma of the peripheral cornea contained several lamellar sutures. The mean lamellar thickness of the peripheral and central KC cornea was significantly (p<0.0001) thinner than the corresponding areas of the normal cornea. CONCLUSION: The present study reveals the involvement of lamellae in the peripheral stroma in the pathogenicity of the KC cornea. The emergence of small undulations in the DM suggests that the formation of undulation might be starting from the DM.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Alkanaan A, Barsotti R, Kirat O, et al. Ultrastructural study of peripheral and central stroma of keratoconus cornea. Br J Ophthalmol. 2017. PMID: 28416495. doi:10.1136/bjophthalmol-2016-309834

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。