儿童圆锥角膜序贯行角膜内环段植入与交联术的安全性与视力结局
回顾性干预病例系列纳入12例(17眼)≤14岁圆锥角膜且矫正远视力差患儿,行飞秒激光辅助角膜内环段植入后1个月交联。6个月随访时平均矫正远视力从0.30±0.19 logMAR显著提高至0.12±0.1 logMAR(P=.001),裸眼远视力亦显著改善,角膜曲率与等效球镜(从-4.0降至-1.56屈光度)显著下降;除1枚环段因血管化与角膜变薄于2年时取出外,无其他并发症。
要点
- 6个月随访时平均矫正远视力从术前0.30±0.19 logMAR显著提高至0.12±0.1 logMAR(P=.001)。
- 6个月随访时平均裸眼远视力从0.90±0.50 logMAR显著改善至0.43±0.31 logMAR。
- 除1枚环段因血管化与角膜变薄于2年时取出外,无术中或术后并发症报告。
核心结论
- 作者认为,角膜内环段植入是儿童圆锥角膜且矫正远视力差者视觉康复的安全有效方法。
研究设计与样本
- 回顾性干预病例系列,纳入年龄≤14岁、矫正远视力差的圆锥角膜患儿,行飞秒激光制作角膜隧道后植入角膜内环段,1个月后行交联术。
- 共12例患者17眼(10男2女),年龄9-14岁(平均12.3岁),随访时间6个月至4年。
- 6个月随访时全部眼均评估,1年、2年、4年随访分别评估11眼、10眼、7眼。
主要发现
- 6个月随访时平均矫正远视力从术前0.30±0.19 logMAR显著提高至0.12±0.1 logMAR(P=.001)。
- 6个月随访时平均裸眼远视力从0.90±0.50 logMAR显著改善至0.43±0.31 logMAR。
- 角膜内环段植入后角膜曲率读数与等效球镜(从-4.0降至-1.56屈光度)均显著下降。
- 1年、2年、4年随访时屈光值较6个月随访相对稳定,但柱镜有轻微但显著的改善,4年时裸眼远视力亦有轻微但显著的改善。
- 所有患者耐受手术良好,无术中或术后并发症报告, except 1枚环段因血管化与角膜变薄于2年后取出。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the safety and visual outcome of intracorneal ring segment (ICRS) implantation followed by cross-linking in pediatric keratoconus patients. DESIGN: Retrospective interventional case series. METHODS: This retrospective study included pediatric patients (aged ≤14 years) with keratoconus and poor corrected distance visual acuity (CDVA) that underwent ICRS implantation and cross-linking (CXL). ICRS were inserted under topical anesthesia after creating a corneal tunnel with a femtosecond laser. Cross-linking was performed 1 month subsequently. Records were reviewed and data collected preoperatively and at 6 months, 1 year, 2 years, and 4 years postoperatively. RESULTS: Twelve patients (17 eyes; 10 male, 2 female) aged 9-14 years (mean age 12.3 years) received ICRS implantation followed by CXL. Follow-up times ranged from 6 months to 4 years after surgery. At the 6-month follow-up all eyes were evaluated; at the 1-year, 2-year, and 4-year follow-up 11, 10, and 7 eyes were evaluated, respectively. At the 6-month follow-up, mean CDVA in comparison to preoperative levels improved significantly (P = .001) from 0.30 ± 0.19 logMAR to 0.12 ± 0.1 logMAR; mean uncorrected distance visual acuity (UDVA) also improved significantly from 0.90 ± 0.50 logMAR to 0.43 ± 0.31 logMAR. A significant decrease in both keratometry readings and spherical equivalent (from -4.0 to -1.56 diopters) was also noted after ICRS insertion. At the 1-year, 2-year, and 4-year follow-up refractive values remained relatively stable in comparison to the 6-month follow-up, except for a minor but significant improvement in cylinder and, at 4 years, in UDVA. All patients tolerated the surgery well and no intraoperative or postoperative complications were reported, except for 1 ring segment that had to be removed after 2 years owing to vascularization and corneal thinning. CONCLUSION: ICRS implantation is a safe and effective procedure for visual rehabilitation in children with keratoconus and poor CDVA.
引用
- Abdelmassih Y, El-Khoury S, Dirani A, et al. Safety and Efficacy of Sequential Intracorneal Ring Segment Implantation and Cross-linking in Pediatric Keratoconus. Am J Ophthalmol. 2017. PMID: 28341606. doi:10.1016/j.ajo.2017.03.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。