患者报告的眼镜独立性问卷(PRSIQ):开发与验证
本研究开发并验证了用于量化白内障术后眼镜独立性的患者报告问卷PRSIQ。通过文献回顾、专家临床访谈和患者访谈开发条目,经认知访谈修订后,在2项定量研究中采用验证性因子分析和条目反应理论校准进行评估。所有定量分析均符合预测,支持PRSIQ总分作为眼镜独立性的测量工具。
要点
- 定性研究发现患者常自认眼镜独立,但追问后发现其特定活动仍戴矫正。
- PRSIQ通过评估患者所言、所行及不同距离的功能来评定眼镜独立性。
- 所有定量分析符合预测,支持PRSIQ总分作为眼镜独立性的测量工具。
核心结论
- PRSIQ是一种评估白内障术后眼镜独立性的患者报告测量工具。
- 所进行的分析为使用PRSIQ总分作为眼镜独立性测量提供了证据。
研究设计与样本
- 问卷设计与验证研究,通过文献回顾、专家临床访谈和患者访谈开发条目。
- 条目在系列认知访谈中评估并修订,最终条目在2项定量研究中评估。
- 采用验证性因子分析(含条目反应理论校准),评估信度并验证效度。
主要发现
- 定性研究显示患者常自认眼镜独立,但追问后发现其特定活动实际仍戴矫正。
- 患者自述的矫正需求与实际使用矫正之间存在差异,且在不同距离无矫正活动时报告了不同功能水平。
- 所有定量分析(如判别效度与聚合效度相关性、已知组分析)符合预测。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To develop a questionnaire quantifying spectacle independence following cataract surgery. DESIGN: Questionnaire design and validation study. METHODS: A literature review, expert clinical interviews, and patient interviews were undertaken to develop a patient-reported questionnaire assessing spectacle independence. Draft items were assessed and revised in a series of cognitive interviews where the instructions, recall period, and response categories were evaluated for understandability and consistency. The final draft items were evaluated in 2 quantitative studies. Confirmatory factor analyses, including item response theory calibration, were performed; reliability estimates were obtained; and validity analyses of the resulting scores were carried out. RESULTS: Qualitative research demonstrated that patients often considered themselves spectacle independent yet, when probed, it was determined that the respondent actually wore correction for certain activities. Moreover, despite what the respondents claimed about needing to wear correction and their actual use of correction, there were various levels of function reported when carrying out activities at several different distances without the use of correction. Using the qualitative results, the Patient-Reported Spectacle Independence Questionnaire (PRSIQ) was developed to assess spectacle independence via items that assess what patients say and do, and how they function at various distances. All quantitative analyses (eg, discriminant and convergent validity correlations, known-groups analyses) conform to predictions and support the use of the PRSIQ as a measure of spectacle independence. CONCLUSIONS: The PRSIQ is a patient-reported measure assessing spectacle independence following cataract surgery. The analyses conducted provide evidence for the use of the PRSIQ total score as a measure of spectacle independence.
引用
- Morlock R, Wirth RJ, Tally SR, et al. Patient-Reported Spectacle Independence Questionnaire (PRSIQ): Development and Validation. Am J Ophthalmol. 2017. PMID: 28341605. doi:10.1016/j.ajo.2017.03.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。