文献速递青光眼眼底病与葡萄膜炎

原发性房角关闭与原发性房角关闭青光眼中光学相干断层扫描的血管密度与结构测量

Vessel Density and Structural Measurements of Optical Coherence Tomography in Primary Angle Closure and Primary Angle Closure Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2017-02-28

横断面研究纳入50名对照者77眼、45例原发性房角关闭青光眼(PACG)患者65眼及22例有高眼压史的原发性房角关闭(PAC)患者31眼,用OCT血管成像评估视盘、视盘周围及黄斑区血管密度并与结构测量比较诊断能力。PACG组血管密度与结构测量均显著低于对照组(P < .05);PAC组血管密度与对照组相似(P > .05),但颞上视网膜神经纤维层较对照组显著变薄(127 μm vs 135 μm,P = .01)。作者认为PACG的结构改变早于视网膜血管密度下降。

要点

  • PACG组视盘、视盘周围及黄斑区血管密度与结构测量均显著低于对照组(P < .05)。
  • PAC组血管密度与对照组相似(P > .05),但颞上RNFL较对照组显著变薄(127 μm vs 135 μm,P = .01)。
  • PACG诊断AUC:视盘内血管密度0.76、黄斑区0.69,低于视盘缘面积0.90与GCC厚度0.91。

核心结论

  • 结果提示PACG的结构改变早于视网膜血管密度下降。

研究设计与样本

  • 横断面研究,纳入50名对照者77眼、45例PACG患者65眼及22例有高眼压史的PAC患者31眼,均行OCT成像。

主要发现

  • PACG组所有血管密度与结构测量均显著低于对照组(P < .05)。
  • PAC组血管密度与对照组相似(P > .05),但颞上RNFL较对照组显著变薄(127 μm vs 135 μm,P = .01)。
  • PACG组视盘内血管密度AUC 0.76、95%特异度敏感度42%,黄斑区血管密度AUC 0.69、敏感度18%,均显著低于视盘缘面积(AUC 0.90、敏感度77%)与GCC厚度(AUC 0.91、敏感度55%)(P < .001)。
  • 视盘周围血管密度AUC 0.85、95%特异度敏感度53%,与RNFL厚度(AUC 0.91、敏感度65%)相似(P = 0.25)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the vessel density measurements of the optic nerve head (ONH), peripapillary, and macular regions on optical coherence tomography (OCT) angiography in eyes with primary angle closure (PAC) and primary angle closure glaucoma (PACG), and to compare their diagnostic abilities with the ONH rim area, peripapillary retinal nerve fiber layer (RNFL) thickness, and the macular ganglion cell complex (GCC) thickness measurements on OCT in PACG. DESIGN: Cross-sectional study. METHODS: Seventy-seven eyes of 50 control subjects, 65 eyes of 45 patients with PACG, and 31 eyes of 22 PAC patients with a history of high intraocular pressure underwent imaging with OCT. Area under receiver operating characteristic curves (AUC) and sensitivities at fixed specificities of vessel densities were compared with structural measurements. RESULTS: All the vessel density and structural measurements were significantly lower (P < .05) in the PACG compared with the control group. Vessel densities in the PAC were similar (P > .05) to that of the controls; the superotemporal RNFL, however, was significantly thinner in the PAC group (127 μm vs 135 μm, P = .01). The AUC and sensitivity at 95% specificity of vessel densities within the ONH (0.76 and 42%) and macular region (0.69 and 18%) in PACG were significantly lower P < .001) than ONH rim area (0.90 and 77%) and GCC thickness (0.91 and 55%), respectively. AUC and sensitivity of peripapillary vessel density (0.85 and 53%) were similar (P = 0.25) to RNFL thickness (0.91 and 65%). CONCLUSIONS: These results suggest that structural changes in PACG occur earlier than the reduction in retinal vessel densities.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Rao HL, Pradhan ZS, Weinreb RN, et al. Vessel Density and Structural Measurements of Optical Coherence Tomography in Primary Angle Closure and Primary Angle Closure Glaucoma. Am J Ophthalmol. 2017. PMID: 28254626. doi:10.1016/j.ajo.2017.02.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。