后弹力层内皮角膜移植术中再次注气:前房空气填充压力与持续时间的影响
这项前瞻性干预性非随机研究纳入117例后弹力层内皮角膜移植术患者,探讨术中前房空气填充压力与持续时间对植片贴附和再次注气率的影响。结果显示,与正常眼压相比,低眼压和高眼压均增加再次注气风险,空气填充超过2小时可独立降低再次注气风险。
要点
- 再次注气率为27%(95%CI 19%-35%),7%患者需超过1次再次注气。
- 与正常眼压相比,低眼压(HR 8.98)和高眼压(HR 10.63)均增加再次注气风险(P=.006)。
- 空气填充超过2小时独立降低再次注气风险(HR 0.36,P=.003)。
核心结论
- 术后空气填充至少2小时且眼压处于生理范围可能有助于降低再次注气率。
研究设计与样本
- 前瞻性、干预性、非随机研究,纳入117例接受后弹力层内皮角膜移植术的患者,随访3个月。
主要发现
- 32例患者需要再次注气(27%[95%CI 19%-35%]),9例需要超过1次再次注气(7%[95%CI 3%-12%])。
- 与正常眼压相比,低眼压(HR 8.98[95%CI 1.07-75.41])和高眼压(HR 10.63[95%CI 1.44-78.27])增加再次注气风险(P=.006)。
- 空气填充持续时间超过2小时降低再次注气风险(HR 0.36[95%CI 0.18-0.71],P=.003),独立于眼压。
- 术后1个月,空气填充持续时间低于2小时组和高于2小时组的平均内皮细胞丢失分别为13%(95%CI 2%-25%)和23%(95%CI 17%-29%)(P=.126)。
- 术后3个月,上述两组的平均内皮细胞丢失分别为31%(95%CI 17%-42%)和42%(95%CI 32%-52%)(P=.229)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To explore the impact of intracameral air tamponade pressure and duration on graft attachment and rebubbling rates. DESIGN: A prospective, interventional, nonrandomized study. METHODS: setting: Department of Ophthalmology, Charité - Universitätsmedizin Berlin. STUDY POPULATION: One hundred seventeen patients who underwent Descemet membrane endothelial keratoplasty (DMEK). OBSERVATION: Intraocular pressure (IOP) at the end of the surgery, immediately after filling the anterior chamber with air, categorized into low (<10 mm Hg), normal (10-20 mm Hg), and high (>20 mm Hg), and the time until partial removal of the air. MAIN OUTCOME MEASURES: Rebubbling rates and endothelial cell density over a 3-month follow-up period analyzed by a multivariable Cox regression model and an analysis of covariance model. RESULTS: Thirty-two patients required a rebubbling (27% [95% CI 19%-35%]). Nine patients required more than 1 rebubbling (7% [95% CI 3%-12%]). Compared with normal IOP, lower (HR 8.98 [95% CI 1.07-75.41]) and higher IOP (HR 10.63 [95% CI 1.44-78.27]) increased the risk of requiring a rebubbling (P = .006). Independent of the IOP, an air tamponade duration beyond 2 hours reduced the risk of rebubbling (HR 0.36 [95% CI 0.18-0.71, P = .003]). One month after surgery, the mean endothelial cell loss was 13% (95% CI 2%-25%) and 23% (95% CI 17%-29%) in the group with air tamponade duration of below and above 2 hours, respectively (P = .126). At 3 months after surgery, it was 31% (95% CI 17%-42%) and 42% (95% CI 32%-52%) in the respective groups (P = .229). CONCLUSIONS: A postsurgical air tamponade of at least 2 hours with an IOP within the physiological range could help to reduce rebubbling rates.
引用
- Pilger D, Wilkemeyer I, Schroeter J, et al. Rebubbling in Descemet Membrane Endothelial Keratoplasty: Influence of Pressure and Duration of the Intracameral Air Tamponade. Am J Ophthalmol. 2017. PMID: 28342720. doi:10.1016/j.ajo.2017.03.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。