使用SENSIMED Triggerfish接触镜进行24小时眼压监测:睡眠期间体位的影响
这项前瞻性、随机、交叉、开放标签比较研究用SENSIMED Triggerfish(TF)接触镜对12例进展性原发性开角型青光眼或基于近期或反复视盘出血诊断的正常眼压性青光眼患者进行24小时眼压监测,比较平卧位与30°头高位睡眠时TF测得的相对眼压差异;两种体位睡眠期均见显著平均正向斜率(p<0.01),体位间TF均值无显著差异(p=0.51),6例(54%)平卧仰卧位TF均值显著更高、4例(36%)头高位更高;佩戴24小时后Goldmann眼压(p=0.001)与TF(p=0.02)测量值显著升高(漂移现象)。
要点
- 两种睡眠体位下睡眠期TF输出均呈显著平均正向斜率(p<0.01)。
- 体位间TF均值无显著差异(p=0.51),但6例(54%)平卧仰卧位更高、4例(36%)头高位更高。
- 佩戴TF 24小时后Goldmann眼压(p=0.001)与TF(p=0.02)测量值显著升高,原文称漂移现象。
核心结论
- 睡眠体位会影响部分进展性青光眼患者经TF测得的眼压。
- 超过50%的受试者出现TF输出向上漂移,需进一步研究以确定该随时间增加的输出值是TF所致伪影还是眼压的真实变化。
研究设计与样本
- 前瞻性、随机、交叉、开放标签比较研究。
- 12例进展性原发性开角型青光眼或正常眼压性青光眼患者完成研究,后者基于近期或反复视盘出血。
- 用TF接触镜在两个独立时段各监测24小时眼压,患者被随机分配一晚平卧睡眠、另一晚30°头高位睡眠。
- 睡眠期定义为22:00-6:00,清醒期定义为8:00-22:00;计算每个时段的睡眠期与清醒期TF均值及清醒-睡眠和睡眠-清醒斜率。
主要发现
- 两种体位睡眠期均见显著平均正向斜率(p<0.01)。
- 体位间TF均值无显著差异(p=0.51)。
- 6例(54%)受试者平卧仰卧位时段TF均值显著更高,4例(36%)受试者头高位时段更高。
- 佩戴TF 24小时后Goldmann眼压(p=0.001)与TF(p=0.02)测量值显著升高,原文称漂移现象。
关键数值与推荐
- 睡眠期:22:00-6:00;清醒期:8:00-22:00。
- 两种体位睡眠期平均斜率均为正向(p<0.01)。
- 体位间TF均值比较p=0.51。
- 6例(54%)平卧仰卧位TF均值显著更高,4例(36%)头高位更高。
- 佩戴24小时后Goldmann眼压p=0.001、TF p=0.02显著升高。
临床怎么用
- 原文未据此给出推荐。
局限性
- 超过50%的受试者出现TF输出向上漂移,需进一步研究以确定该输出值随时间增加是TF所致伪影还是眼压的真实变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine the difference in relative intraocular pressure (IOP) measured by the SENSIMED Triggerfish (TF) contact lens in flat compared with 30° head-up sleeping positions in patients with progressive primary open-angle glaucoma or normotensive glaucoma, based on recent or recurrent disc haemorrhage. DESIGN: Prospective, randomised, cross-over, open-label comparative study. METHODS: IOP was monitored for 24 hours using TF on two separate sessions. Patients were randomly assigned to sleep flat one night and 30° head-up the other. Outputs in arbitrary units were obtained. Sleep and wake periods were defined as 22:00-6:00 and 8:00-22:00, respectively. Mean TF values during sleep and wake periods and wake-sleep and sleep-wake slopes were calculated for each session. TF output signals were compared between positions. RESULTS: Twelve subjects completed the study. Significant mean positive slopes were noted during the sleep period for both positions (p<0.01). No significant differences in the TF mean values were observed between positions (p=0.51). Six (54%) subjects had mean TF values significantly higher during the flat supine session, while four (36%) subjects had higher values during the head-up session. A significant increase in Goldmann IOP (p=0.001) and TF (p=0.02) measurements were observed after 24 hours of TF wear ('drift phenomenon'). CONCLUSIONS: Sleep position affects IOP as measured by TF in some patients with progressive glaucoma. The upward drift in TF output detected in >50% of the subjects requires further investigation to establish whether the increased output values over time are an artefact induced by the TF or a real change in IOP. TRIAL REGISTRATION NUMBER: NCT01351779.
引用
- Beltran-Agulló L, Buys YM, Jahan F, et al. Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep. Br J Ophthalmol. 2017. PMID: 28270491. doi:10.1136/bjophthalmol-2016-308710
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。