文献速递青光眼

选择性激光小梁成形术的作用机制及反应预测因素

Mechanism of Action of Selective Laser Trabeculoplasty and Predictors of Response.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

这项前瞻性观察研究纳入31例拟以选择性激光小梁成形术(SLT)作为首选降眼压治疗的高眼压症或原发性开角型青光眼连续病例,基线及术后3个月测量房水动力学。SLT后9时与中午眼压显著下降,荧光光度法与眼压描记测得的房水外流易度均显著升高,房水流量与巩膜外静脉压无变化,对侧未治疗眼无变化。作者结论为SLT降眼压通过增加房水外流易度实现,基线房水流量较高与外流易度较低可能预测更好的反应。

要点

  • SLT后9时眼压22.9±5.1 vs 19.7±3.0 mm Hg(P=0.001),中午23.4±4.6 vs 20.0±3.5 mm Hg(P<0.001)。
  • 荧光光度法房水外流易度由0.17±0.11升至0.24±0.14 μL/min/mm Hg(P=0.008),眼压描记法同样升高。
  • 对侧未治疗眼眼压与房水动力学均无变化。

核心结论

  • SLT的降眼压效应通过增加房水外流易度介导,无对侧效应;基线房水流量较高与外流易度较低可能预测对SLT更好的反应。

研究设计与样本

  • 前瞻性观察研究,纳入31例诊断为高眼压症或原发性开角型青光眼、计划以SLT作为首选降眼压治疗的连续病例,双眼基线评估房水动力学,全部行360度SLT,3个月后重复测量。

主要发现

  • 与基线相比,SLT后9时眼压显著降低(22.9±5.1 vs 19.7±3.0 mm Hg;P=0.001),中午眼压显著降低(23.4±4.6 vs 20.0±3.5 mm Hg;P<0.001)。
  • 荧光光度法房水外流易度由基线0.17±0.11 μL/min/mm Hg显著升至3个月时0.24±0.14 μL/min/mm Hg(P=0.008)。
  • 眼压描记法房水外流易度由基线0.16±0.07 μL/min/mm Hg升至3个月时0.22±0.16 μL/min/mm Hg(P=0.046)。
  • 未观察到房水流量或巩膜外静脉压(EVP)的变化;对侧未治疗眼的眼压与房水动力学均无变化。
  • 多因素线性回归模型显示,基线房水流量较高、基线房水外流易度较低以及可能较低的葡萄膜巩膜外流与SLT降眼压幅度更大相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study was designed to evaluate the changes in aqueous humor dynamics (AHD) produced by selective laser trabeculoplasty (SLT) and to explore if baseline AHD parameters are predictive of IOP response to SLT. METHODS: Thirty-one consecutive subjects diagnosed with ocular hypertension or primary open-angle glaucoma scheduled to undergo SLT as their primary IOP-lowering therapy were enrolled in this prospective observational study. Subjects underwent baseline assessment of AHD in both eyes. Variables assessed were IOPs at 9 AM and noon, aqueous humor flow rate (fluorophotometry), episcleral venous pressure (EVP, venomanometry), outflow facility (pneumatonography and fluorophotometry) and uveoscleral outflow (calculated using modified Goldmann equation). All subjects underwent 360 degrees SLT and AHD measurements were repeated 3 months later. RESULTS: Compared with baseline, IOPs after SLT were significantly lower at 9 AM (22.9 ± 5.1 vs. 19.7 ± 3.0 mm Hg; P = 0.001) and noon (23.4 ± 4.6 vs. 20.0 ± 3.5 mm Hg; P < 0.001). Outflow facility by fluorophotometry was significantly increased from 0.17 ± 0.11 μL/min/mm Hg at baseline to 0.24 ± 0.14 μL/min/mm Hg at 3 months (P = 0.008). Outflow facility by tonography (baseline: 0.16 ± 0.07 μL/min/mm Hg vs. 3 months: 0.22 ± 0.16 μL/min/mm Hg; P = 0.046) was similarly increased. No change in aqueous flow or EVP was observed. There were no changes in IOP or AHD in the contralateral untreated eye. Using multiple linear regression models, higher baseline aqueous flow, lower baseline outflow facility, and possibly lower uvescleral outflow were associated with more IOP lowering with SLT. CONCLUSIONS: The IOP-lowering effect of SLT is mediated through an increase in outflow facility. There is no contralateral effect. Higher aqueous flow and lower outflow facility may be predictive of better response to SLT.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Gulati V, Fan S, Gardner BJ, et al. Mechanism of Action of Selective Laser Trabeculoplasty and Predictors of Response. Invest Ophthalmol Vis Sci. 2017. PMID: 28264102. doi:10.1167/iovs.16-20710

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。