青光眼中结构与功能指标与对比敏感度的关联
这项横断面前瞻性研究纳入65例患者共105只青光眼眼,在同一天完成黄斑频域OCT、24-2标准自动视野和对比敏感度测量,发现结构与功能指标和对比敏感度呈一般性关联,其中6周/度对比敏感度与黄斑全层厚度及中央视野参数相关性最强;在本横断面研究中对比敏感度并非青光眼严重程度的可靠替代指标。
要点
- 6周/度对比敏感度与颞下及鼻下黄斑区神经节细胞/内丛状层厚度相关(ρ=0.222,P=.023;ρ=0.209,P=.032)。
- 6周/度对比敏感度与上方6×3度区域中央黄斑厚度相关性最强(ρ=0.311,P=.001)。
- 6周/度对比敏感度与4个中央视野点平均偏差相关性最强(ρ=-0.420,P<.001)。
核心结论
- 结构与功能指标与对比敏感度呈一般性关联,该关联在黄斑全层厚度或中央视野参数与6周/度对比敏感度之间最为突出。
- 在本横断面研究中,对比敏感度并非青光眼严重程度的可靠替代指标。
研究设计与样本
- 横断面前瞻性研究,纳入65例患者共105只眼,在同一天完成黄斑频域光学相干断层扫描、24-2标准消色差视野和对比敏感度测量。
- 采用相关与回归分析探讨3、6、12、18周/度4个空间频率的对比敏感度与结构与功能指标之间的关联。
主要发现
- 24-2视野平均偏差的中位数(四分位距)为-7.6(-11.1至-3.0)。
- 6周/度对比敏感度与颞下及鼻下黄斑区神经节细胞/内丛状层厚度显著相关(ρ=0.222,P=.023;ρ=0.209,P=.032)。
- 6周/度对比敏感度与黄斑全层厚度测量值相关性更高,其中与上方6×3度区域中央黄斑厚度相关性最强(ρ=0.311,P=.001)。
- 6周/度对比敏感度与4个中央视野点平均偏差相关性最强(ρ=-0.420,P<.001)。
- logMAR视力与6、12、18周/度对比敏感度显著相关(ρ=-0.306、ρ=-0.348、ρ=-0.241,P<.013)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To test the hypothesis that structural and functional measures predict contrast sensitivity (CS) outcomes in glaucomatous eyes. DESIGN: Cross-sectional prospective study. METHODS: One hundred five eyes of 65 patients who underwent macular spectral-domain optical coherence tomography imaging, 24-2 standard achromatic visual fields (VF), and CS measurement on the same day were enrolled. Association of CS at 4 spatial frequencies (3, 6, 12, and 18 cycles per degree, cpd) with structural and functional outcomes was explored with correlation and regression analyses. RESULTS: The median (IQR) 24-2 visual field mean deviation was -7.6 (-11.1 to -3.0). Significant correlations were found between CS at 6 cpd and ganglion cell/inner plexiform layer thickness at inferotemporal and inferonasal macular sectors (ρ = 0.222, P = .023 and ρ = 0.209, P = .032, respectively). CS at 6 cpd demonstrated higher correlations with full macular thickness measurements, the strongest of which was with the central macular thickness in the superior 6 × 3-degree region (ρ = 0.311, P = .001). Contrast sensitivity at 6 cpd also had the strongest correlation with mean deviation of the 4 central VF points (ρ = -0.420; P < .001). There was a significant correlation between logMAR visual acuity and contrast sensitivity at 6, 12, and 18 cpd (ρ = -0.306, ρ = -0.348 and ρ = -0.241, P < .013, respectively). CONCLUSIONS: Structural and functional measures showed a fair relationship with contrast sensitivity. This association was most prominent between full-thickness macular measures or central VF parameters and CS at 6 cpd. Contrast sensitivity was not a reliable surrogate for glaucoma severity in this cross-sectional study.
引用
- Fatehi N, Nowroozizadeh S, Henry S, et al. Association of Structural and Functional Measures With Contrast Sensitivity in Glaucoma. Am J Ophthalmol. 2017. PMID: 28342719. doi:10.1016/j.ajo.2017.03.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。