文献速递眼底病与葡萄膜炎

外层视网膜厚度可作为糖尿病黄斑水肿患者良好的视力预测指标

OUTER RETINAL LAYER THICKNESS AS GOOD VISUAL PREDICTOR IN PATIENTS WITH DIABETIC MACULAR EDEMA.
PubMed 文献 · Retina · 2018-01-01

这项前瞻性非随机病例对照研究纳入95只眼,比较健康正常眼30只与非增殖性糖尿病视网膜病变伴糖尿病黄斑水肿眼65只,发现黄斑水肿组外层视网膜厚度显著薄于对照组,且外层视网膜厚度与logMAR视力相关性高于中心凹中心点厚度与视力的相关性。

要点

  • 糖尿病黄斑水肿组外层视网膜厚度为85.3 μm,显著薄于对照组的99.9 μm(P=0.002)。
  • 外层视网膜厚度与logMAR视力相关性(r=-0.87,P<0.001)高于中心凹中心点厚度与视力的相关性(r=0.18,P=0.16)。
  • 外层视网膜厚度与视力关系的截断点为88 μm,灵敏度81%、特异度88%,低于该值视力受影响。

核心结论

  • 本研究揭示糖尿病黄斑水肿中外层视网膜厚度变薄,且外层视网膜厚度与视力的相关性高于中心凹中心点厚度与视力的相关性。

研究设计与样本

  • 前瞻性非随机病例对照研究,纳入95只眼,分为健康正常对照30只眼和非增殖性糖尿病视网膜病变伴糖尿病黄斑水肿65只眼。
  • 所有病例完成完整眼科检查和谱域光学相干断层扫描,测量中心凹中心点厚度、黄斑中心凹外层视网膜厚度和中心凹下脉络膜厚度。

主要发现

  • 外层视网膜厚度在糖尿病黄斑水肿组为85.3 μm,显著薄于对照组的99.9 μm(P=0.002)。
  • 外层视网膜厚度与logMAR视力的相关性(r=-0.87,P<0.001)高于中心凹中心点厚度与视力的相关性(r=0.18,P=0.16)。
  • 外层视网膜厚度与视力关系的截断点为88 μm,灵敏度81%、特异度88%,低于该值视力受影响。
  • 外层视网膜厚度与中心凹下脉络膜厚度显著相关,但与中心凹中心点厚度不相关。

关键数值与推荐

  • 外层视网膜厚度与视力关系的截断点为88 μm,灵敏度81%、特异度88%,低于该值视力受影响。
  • 外层视网膜厚度与logMAR视力相关系数r=-0.87(P<0.001),中心凹中心点厚度与视力相关系数r=0.18(P=0.16)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the relationship between outer retinal layer (ORL) thickness in diabetic macular edema to visual acuity (VA). METHODS: Ninety-five eyes were included in this prospective nonrandomized case-control study. They divided into 30 cases of healthy normal subjects and 65 cases of nonproliferative diabetic retinopathy with diabetic macular edema. Complete ophthalmic examination and spectral domain-optical coherence tomography were done for all cases and analyzed to measure central foveal point thickness (CFT), ORL thickness at fovea, and subfoveal choroidal thickness. RESULTS: The ORL thickness was significantly thinner in diabetic macular edema group (85.3 μm) than controls (99.9 μm) (P = 0.002). There was higher significant correlation between ORL thickness and logMAR VA (r = -0.87, P < 0.001) than correlation between CFT and VA (r = 0.18, P = 0.16). The cutoff point of the relationship between ORL thickness and VA was 88 μm with moderate sensitivity (81%) and high specificity (88%), below which vision is affected. Outer retinal layer thickness is significantly related to subfoveal choroidal thickness but not CFT. CONCLUSION: This study revealed reduction in ORL thickness in diabetic macular edema. There is a higher and stronger correlation between ORL thickness and vision than that between CFT and vision.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Eliwa TF, Hussein MA, Zaki MA, et al. OUTER RETINAL LAYER THICKNESS AS GOOD VISUAL PREDICTOR IN PATIENTS WITH DIABETIC MACULAR EDEMA. Retina. 2018. PMID: 28333881. doi:10.1097/IAE.0000000000001599

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。