文献速递眼底病与葡萄膜炎

特发性玻璃体黄斑牵拉患者中心凹厚度与视力的相关性

CORRELATION BETWEEN CENTRAL FOVEAL THICKNESS AND VISUAL ACUITY IN PATIENTS WITH IDIOPATHIC VITREOMACULAR TRACTION.
PubMed 文献 · Retina · 2018-01-01

回顾性评估35例特发性玻璃体黄斑牵拉患者术前中心凹厚度(CFT)对术后视力的影响,并计算术前CFT的临界值。术后12个月平均CFT较基线显著下降(P=0.001);术前CFT与视力改善无显著相关(r=-0.090,P=0.605),与术前视力显著相关(r=0.757,P<0.001);CFT改善与视力改善显著相关(r=0.449,P=0.007);受试者工作特征分析得出阈值CFT为471 μm,CFT<471 μm的15例患者中术前CFT与术后视力改善显著相关(r=0.561,P=0.030)。

要点

  • 35例特发性玻璃体黄斑牵拉患者术后12个月平均CFT较基线显著下降(P=0.001)。
  • 术前CFT与视力改善无显著相关(r=-0.090,P=0.605),与术前视力显著相关(r=0.757,P<0.001)。
  • 受试者工作特征分析得出阈值CFT为471 μm。

核心结论

  • 术前CFT对特发性玻璃体黄斑牵拉患者的视力预后重要,作者认为这些患者的术前CFT应在手术决策中予以考虑。

研究设计与样本

  • 回顾性评估35例特发性玻璃体黄斑牵拉患者,术前及术后12个月行包括频域光学相干断层扫描的完整眼科检查,采用受试者工作特征分析确定与视力改善≥10个早期治疗糖尿病视网膜病变研究字母相关的CFT临界点。

主要发现

  • 35例患者术后12个月平均CFT较基线显著下降(P=0.001)。
  • 术前CFT与视力改善无显著相关(r=-0.090,P=0.605),而术前CFT与术前视力显著相关(r=0.757,P<0.001)。
  • CFT改善与视力改善也显著相关(r=0.449,P=0.007)。
  • 受试者工作特征分析得出阈值CFT为471 μm。
  • CFT<471 μm的15例患者中,术前CFT与术后视力改善显著相关(r=0.561,P=0.030)。

关键数值与推荐

  • 受试者工作特征分析得出的阈值CFT为471 μm,用于关联早期治疗糖尿病视网膜病变研究视力表上≥10个字母的视力改善。

临床怎么用

  • 作者认为术前CFT对特发性玻璃体黄斑牵拉患者的视力预后重要,这些患者的术前CFT应在手术决策中予以考虑。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the impact of preoperative central foveal thickness (CFT) on visual acuity after surgery in patients with idiopathic vitreomacular traction and to calculate a cut-off value in preoperative CFT. METHODS: Thirty-five patients with idiopathic vitreomacular traction were evaluated retrospectively. A complete ophthalmological examination including spectral domain optical coherence tomography was performed preoperatively and at 12 months after the surgery. Receiver operating characteristic analysis was used to determine the critical point for the CFT associated with improvement of 10 or more letters in visual acuity on the Early Treatment Diabetic Retinopathy Study. RESULTS: Among 35 patients, the mean CFT at postoperative 12 months was significantly decreased from baseline (P = 0.001). Preoperative CFT and visual improvement were not significantly correlated (r = -0.090, P = 0.605), whereas preoperative CFT and preoperative visual acuity were significantly correlated (r = 0.757, P < 0.001). Improvement in CFT and visual improvement were also correlated significantly (r = 0.449, P = 0.007). According to the receiver operating characteristic analysis, the threshold CFT was 471 μm. When 15 patients with CFT thickness under 471 μm were evaluated, preoperative CFT was significantly correlated with improvement in visual acuity after the surgery (r = 0.561, P = 0.030). CONCLUSION: Preoperative CFT is important for the visual prognosis of patients with vitreomacular traction. Preoperative CFT of these patients should be considered in surgical decisions.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Uzel MM, Citirik M, Ilhan C, et al. CORRELATION BETWEEN CENTRAL FOVEAL THICKNESS AND VISUAL ACUITY IN PATIENTS WITH IDIOPATHIC VITREOMACULAR TRACTION. Retina. 2018. PMID: 28338558. doi:10.1097/IAE.0000000000001635

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。