文献速递小儿眼科与斜弱视

前节光学相干断层扫描测量成人斜视手术患者直肌止点位置的准确性

Accuracy of Optical Coherence Tomography Measurements of Rectus Muscle Insertions in Adult Patients Undergoing Strabismus Surgery.
PubMed 文献 · Am J Ophthalmol · 2017-02-03

本研究为信度分析,纳入74例拟行直肌斜视手术的成人患者,术前用前节光学相干断层扫描(AS-OCT)测量直肌止点至角膜缘的距离,并与术中卡尺测量值比较,共分析144条肌肉。AS-OCT测量值与术中测量值相差≤1 mm者在全部肌肉中占77%,初次手术肌肉为83%,再次手术肌肉为58%;作者结论认为AS-OCT在初次斜视手术中有助于识别眼外肌止点,但再次手术时准确性下降。

要点

  • AS-OCT术前测量直肌止点与术中卡尺测量相差≤1 mm者占全部肌肉的77%。
  • 初次手术肌肉准确率为83%,再次手术肌肉为58%。
  • 内直肌与外直肌再次手术较初次手术准确率下降,但差异无统计学意义。

核心结论

  • AS-OCT在初次斜视手术中有助于识别眼外肌止点,但再次手术时准确性下降。

研究设计与样本

  • 信度分析,机构临床实践环境,纳入74例拟行直肌斜视手术的成人患者,共分析144条肌肉。

主要发现

  • 33条再次手术肌肉中31条成功成像。
  • AS-OCT测量值与术中测量值相差≤1 mm者在全部肌肉中占77%,无既往手术肌肉为83%,再次手术肌肉为58%。
  • 内直肌再次手术与初次手术准确率比较为63%对79%(P = .09;95%CI,-1.38至0.11),差异无统计学意义。
  • 外直肌再次手术与初次手术准确率比较为49%对81%(P = .11;95%CI,-2.06至0.22),差异无统计学意义。
  • 角膜缘至前房角距离与眼轴长度之间未建立相关性。

关键数值与推荐

  • 临床可接受的判定标准为术前AS-OCT与术中测量差值≤1 mm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the accuracy of anterior segment optical coherence tomography (AS-OCT) in measuring the distance of extraocular muscle (EOM) insertion to the limbus to improve preoperative assessment of adult patients undergoing strabismus surgery. DESIGN: Reliability analysis. METHODS: setting: An institutional practice. PATIENT POPULATION: Seventy-four adult patients scheduled for strabismus surgery on rectus muscles. OBSERVATION PROCEDURE: The distance between the EOM insertion and the limbus was measured preoperatively with AS-OCT. The value was compared with the intraoperative measurement obtained with calipers. Additional measurements included the limbus-anterior chamber angle distance with AS-OCT and the axial length with IOLMaster. MAIN OUTCOME MEASURE: Agreement between preoperative AS-OCT and intraoperative measurements. A difference of ≤1 mm was "clinically acceptable." RESULTS: A total of 144 muscles were analyzed. Thirty-one of 33 reoperated muscles were successfully imaged. AS-OCT measurements were within 1 mm of intraoperative measurements in 77% of all muscles. The accuracy was higher for muscles with no prior surgery (83%), as compared with reoperated muscles (58%). Although the accuracy decreased when comparing reoperations to primary surgeries for the medial (79% to 63%; P = .09; 95% confidence interval [CI], -1.38 to 0.11) and the lateral rectus (81% to 49%; P = .11; 95% CI, -2.06 to 0.22), the difference was not significant. No correlation between limbus-anterior chamber angle distance and axial length was established. CONCLUSIONS: AS-OCT is valuable in identifying EOM insertions in primary strabismus surgeries, but the accuracy decreases in reoperations.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Rossetto JD, Cavuoto KM, Allemann N, et al. Accuracy of Optical Coherence Tomography Measurements of Rectus Muscle Insertions in Adult Patients Undergoing Strabismus Surgery. Am J Ophthalmol. 2017. PMID: 28163119. doi:10.1016/j.ajo.2017.01.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。