文献速递白内障与屈光手术角膜与眼表疾病

圆锥角膜候选者中光线追踪与基于前表面的角膜曲率测量对角膜散光的测量比较

Corneal Astigmatism Measurement by Ray Tracing Versus Anterior Surface-Based Keratometry in Candidates for Toric Intraocular Lens Implantation.
PubMed 文献 · Am J Ophthalmol · 2017-02-06

该可靠性分析纳入200例连续白内障患者(平均年龄71±9岁)的1只眼,用Pentacam HR测量光线追踪法得出的全角膜屈光力散光(CATCRP)与基于前表面的模拟角膜曲率散光(CASimK)。77例CATCRP>1D的环曲面人工晶状体候选眼中,CASimK在22%的病例中<1D,平均低估散光-0.15±0.34D;两法绝对差和矢量差>0.50D的比例分别为27.2%和32.5%,显著高于CATCRP≤1D眼(0.8%和9.8%,P<.001)。结论认为两法差异在候选眼中大于一般人群,并在较大比例病例中影响候选眼和环曲面人工晶状体度数选择。

要点

  • 77例环曲面人工晶状体候选眼中,CASimK在22%的病例中<1D,平均低估散光-0.15±0.34D。
  • 候选眼中两法绝对差和矢量差>0.50D的比例分别为27.2%和32.5%,显著高于CATCRP≤1D眼(0.8%和9.8%,P<.001)。
  • 候选眼中两法陡峭子午线对齐差异>5度占22.1%,>10度占2.6%。

核心结论

  • Pentacam HR计算的光线追踪法CATCRP与基于前表面的CASimK之间的差异在环曲面人工晶状体候选眼中大于一般人群。
  • 该差异在较大比例病例中相当程度影响候选眼和环曲面人工晶状体度数选择。

研究设计与样本

  • 可靠性分析,纳入200例连续白内障患者的1只眼,平均年龄71±9岁,使用Pentacam HR(Oculus)测量CATCRP和CASimK。
  • CATCRP>1D的眼定义为环曲面人工晶状体植入候选眼。
  • 通过计算两法间的算术差、绝对差和矢量差分析估计差异。

主要发现

  • 识别出77例候选眼。
  • 候选眼中CASimK<1D占22%,平均低估散光-0.15±0.34D。
  • 候选眼中CATCRP与CASimK的平均绝对差为0.31±0.29D,平均矢量差为0.30±0.29D×180度。
  • 候选眼中两法绝对差>0.50D为21/77(27.2%),矢量差>0.50D为25/77(32.5%),显著高于CATCRP≤1D眼(分别为0.8%和9.8%,P<.001)。
  • 候选眼中两法陡峭子午线对齐差异>5度占22.1%,>10度占2.6%。

关键数值与推荐

  • 环曲面人工晶状体植入候选眼定义为CATCRP>1D。
  • 候选眼中CASimK<1D占22%,平均低估散光-0.15±0.34D。
  • 候选眼中两法绝对差>0.50D占27.2%,矢量差>0.50D占32.5%,均显著高于CATCRP≤1D眼的0.8%和9.8%(P<.001)。
  • 候选眼中陡峭子午线对齐差异>5度占22.1%,>10度占2.6%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare corneal astigmatism derived from total corneal refractive power (CATCRP), a ray-tracing method, with that derived from simulated keratometry (CASimK), an anterior surface-based method, in candidates for toric intraocular lens (IOL) implantation. DESIGN: Reliability analysis. METHODS: In 1 eye of 200 consecutive patients (mean age 71 ± 9 years) with cataract, a Pentacam HR (Oculus) was used to measure CATCRP and CASimK. Eyes with CATCRP >1 diopter (D) were defined as candidates for toric IOL implantation. The estimation difference between CATCRP and CASimK was analyzed by calculating the arithmetic, absolute, and vector differences between the 2 methods. RESULTS: Seventy-seven candidates were identified. In the candidates, CASimK was <1 D in 22% of cases and underestimated the astigmatism magnitude, on average, by -0.15 ± 0.34 D. The mean absolute and vector difference between CATCRP and CASimK was 0.31 ± 0.29 D and 0.30 ± 0.29 D × 180 degrees, respectively. The absolute and vector differences between the 2 methods were >0.50 D in 21 of 77 (27.2%) and 25 of 77 (32.5%) eyes, respectively; the proportions were significantly (P < .001) higher than in the eyes with CATCRP ≤1 D (0.8% and 9.8%, respectively). The difference in steep meridian alignment between CATCRP and CASimK was >5 degrees in 22.1% and >10 degrees in 2.6% of cases. CONCLUSION: The difference between CATCRP and CASimK, as calculated by Pentacam HR, is greater in candidates for toric IOL implantation than in the general population. That difference considerably influences the candidate and toric IOL power selection in a large proportion of cases.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. de Sanctis U, Donna P, Penna RR, et al. Corneal Astigmatism Measurement by Ray Tracing Versus Anterior Surface-Based Keratometry in Candidates for Toric Intraocular Lens Implantation. Am J Ophthalmol. 2017. PMID: 28185842. doi:10.1016/j.ajo.2017.01.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。