活体非人灵长类眼前房水造影显示节段性、搏动性和动态性房水流出
本研究为横断面观察性研究,在6只活体非人灵长类动物眼内安全开展前房水造影,使用吲哚菁绿(ICG)或荧光素钠在重力驱动恒压系统下注入前房,联合前节OCT成像。结果显示房水造影模式大多稳定,阳性信号与表层巩膜静脉及巩膜内腔共定位,有时呈搏动性,并可动态变化,出现新阳性或信号消失区域。
要点
- 活体非人灵长类眼可安全进行前房水造影,评估房水流出通道。
- 造影阳性信号与红外成像识别的表层巩膜静脉及前节OCT显示的巩膜内腔共定位。
- 房水造影显示节段性、搏动性模式,并可见动态变化(新出现或消失)。
核心结论
- 活体非人灵长类前房水造影显示节段性和搏动性模式,并新描述了动态变化能力。
- 这些特征有助于理解活体房水流出生物学,可能有助于改进针对小梁网旁路的青光眼手术。
研究设计与样本
- 横断面观察性研究,纳入6只非人灵长类动物。
- 麻醉后经颞侧1mm侧切口置入前房维持器,以重力驱动恒压系统向前房内注入0.4%吲哚菁绿(ICG)或2.5%荧光素钠(单独或序贯)。
- 使用Spectralis HRA+OCT(海德堡工程公司,德国海德堡)经定制手术悬臂架于非人灵长类眼上方获取前房水造影图像,并对造影阳性与阴性远端区域同期行前节OCT。
主要发现
- 活体非人灵长类眼前房水造影显示大多稳定的造影模式。
- 多模态成像显示造影阳性信号与红外成像识别的表层巩膜静脉及前节OCT显示的巩膜内腔共定位。
- 同一眼内序贯使用ICG后荧光素钠行前房水造影显示相似的造影模式。
- 有时观察到前房水造影流出呈搏动性。
- 前房水造影模式可动态变化,有时先前无造影信号的区域突然出现阳性造影流,或初始记录到造影信号的区域信号突然消失。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the feasibility of safely performing aqueous angiography in intact eyes of living nonhuman primates (NHPs) for evaluating aqueous humor outflow and segmental patterns. DESIGN: Cross-sectional, observational study. SUBJECTS: Six nonhuman primates. METHODS: Aqueous angiography was performed in 6 nonhuman primates. After anesthesia, an anterior chamber (AC) maintainer was placed through a temporal 1-mm side-port wound. Indocyanine green (ICG; 0.4%) or 2.5% fluorescein was introduced (individually or in sequence) into the eye with a gravity-driven constant-pressure system. Aqueous angiography images were obtained with a Spectralis HRA+OCT (Heidelberg Engineering GmbH, Heidelberg, Germany) suspended over the NHP eye using a custom-designed surgical boom arm. Concurrent anterior segment optical coherence tomography (OCT) was performed on distally angiographically positive and negative regions. MAIN OUTCOME MEASURES: Angiographic patterns described by location, time-course, choice of tracer, and anterior-segment OCT. RESULTS: Aqueous angiography in the living NHP eye demonstrated mostly stable angiographic patterns. With multimodal imaging, angiographically positive signal co-localized with episcleral veins as identified by infrared imaging and intrascleral lumens, as demonstrated by anterior segment OCT. Sequential aqueous angiography in individual eyes with ICG followed by fluorescein showed similar angiographic patterns. A pulsatile nature of aqueous angiographic outflow was sometimes observed. Aqueous angiographic patterns could also dynamically change. In some instances, positive angiographic flow suddenly arose in regions previously without an angiographic signal. Alternatively, an angiographic signal could suddenly disappear from regions in which an angiographic signal was initially documented. CONCLUSIONS: Aqueous angiography in living NHPs demonstrated segmental and pulsatile patterns with a newly described ability to dynamically shift. These characteristics further the understanding of live aqueous humor outflow biology and may be useful in improving glaucoma surgeries aimed at trabecular meshwork bypass.
引用
- Huang AS, Li M, Yang D, et al. Aqueous Angiography in Living Nonhuman Primates Shows Segmental, Pulsatile, and Dynamic Angiographic Aqueous Humor Outflow. Ophthalmology. 2017. PMID: 28237425. doi:10.1016/j.ophtha.2017.01.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。