测量小鼠视神经乳头及视乳头旁巩膜的变形
研究利用多光子显微镜与数字体积相关技术建立离体组织块系统,测量小鼠视神经乳头星形胶质细胞结构和视乳头旁巩膜在眼压变化下的全场变形响应。结果显示急性眼压下星形胶质细胞板中央区鼻颞向应变显著大于上下向和前后向,视乳头旁巩膜开口鼻颞向增宽更明显;慢性眼压升高1至3天后,视乳头旁巩膜面积增大、周长伸长较对照减少37%、全局鼻颞向应变显著减小,星形胶质细胞突起取向发生改变。
要点
- 离体组织块系统可测量小鼠视神经乳头对眼压的应变响应。
- 急性眼压下星形胶质细胞板中央区鼻颞向应变显著大于其他方向。
- 慢性眼压升高后视乳头旁巩膜周长伸长较对照减少37%。
核心结论
- 离体充压试验可测量小鼠视神经乳头对施加眼压的应变响应,初步研究提示视神经乳头区域内对急性和慢性眼压升高的响应存在区域差异。
研究设计与样本
- 离体组织块系统研究,使用绿色荧光蛋白-谷氨酸转运体-GLT1(GLT1/GFP)小鼠眼,在控制充压下以激光扫描显微镜成像,分析区域应变及星形胶质细胞板和视乳头旁巩膜形状变化。
- 测量了7只对照GLT1/GFP小鼠的星形胶质细胞体积分数。
- 用免疫组织化学比较GFP荧光星形胶质细胞与胶质纤维酸性蛋白(GFAP)标记星形胶质细胞的荧光水平。
主要发现
- 视神经乳头星形胶质细胞结构在离体组织块中3小时内保持稳定。
- 对照应变在全局、星形胶质细胞板中央二分之一或三分之二区域,鼻颞向显著大于上下向或前后向(各P≤0.03,混合模型)。
- 正常眼组织块视乳头旁巩膜开口(周长)在充压从10至30 mm Hg过程中鼻颞向增宽大于上下向(P=0.0005)。
- 慢性眼压升高1至3天后,视乳头旁巩膜面积大于对照眼(P=0.035),周长伸长较对照减少37%,全局鼻颞向应变显著小于对照(P=0.007)。
- 慢性眼压升高改变了星形胶质细胞取向,突起重新定向朝向视神经纵轴。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To develop an ex vivo explant system using multiphoton microscopy and digital volume correlation to measure the full-field deformation response to intraocular pressure (IOP) change in the peripapillary sclera (PPS) and in the optic nerve head (ONH) astrocytic structure. METHODS: Green fluorescent protein (GFP)-glutamate transporter-GLT1 (GLT1/GFP) mouse eyes were explanted and imaged with a laser-scanning microscope under controlled inflation. Images were analyzed for regional strains and changes in astrocytic lamina and PPS shape. Astrocyte volume fraction in seven control GLT1/GFP mice was measured. The level of fluorescence of GFP fluorescent astrocytes was compared with glial fibrillary acidic protein (GFAP) labeled astrocytes using immunohistochemistry. RESULTS: The ONH astrocytic structure remained stable during 3 hours in explants. Control strain-globally, in the central one-half or two-thirds of the astrocytic lamina-was significantly greater in the nasal-temporal direction than in the inferior-superior or anterior-posterior directions (each P≤ 0.03, mixed models). The PPS opening (perimeter) in normal eye explants also became wider nasal-temporally than superior-inferiorly during inflation from 10 to 30 mm Hg (P = 0.0005). After 1 to 3 days of chronic IOP elevation, PPS area was larger than in control eyes (P = 0.035), perimeter elongation was 37% less than controls, and global nasal-temporal strain was significantly less than controls (P = 0.007). Astrocyte orientation was altered by chronic IOP elevation, with processes redirected toward the longitudinal axis of the optic nerve. CONCLUSIONS: The explant inflation test measures the strain response of the mouse ONH to applied IOP. Initial studies indicate regional differences in response to both acute and chronic IOP elevation within the ONH region.
引用
- Nguyen C, Midgett D, Kimball EC, et al. Measuring Deformation in the Mouse Optic Nerve Head and Peripapillary Sclera. Invest Ophthalmol Vis Sci. 2017. PMID: 28146237. doi:10.1167/iovs.16-20620
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。