眼压与人免疫缺陷病毒的关联
该回顾性横断面研究纳入2000至2016年间某学术眼科中心的400例患者,比较HIV感染且接受HAART者(176例)、HIV感染未接受HAART者(48例)与无HIV对照者(176例)的平均眼压。结果显示三组平均眼压分别为13.7、13.1与17.3 mmHg(P<.01),CD4计数≤700 cells/mm3与眼压降低相关。
要点
- 三组平均眼压:G1 13.7±5.1 mmHg、G2 13.1±3.6 mmHg、G3 17.3±3.8 mmHg,P<.01。
- CD4计数≤700 cells/mm3者眼压降低2.1 mmHg。
- HIV感染者眼压≤10 mmHg的可能性为对照的7倍,CD4计数≤700 cells/mm3者为13倍。
核心结论
- 绝对CD4计数可能在眼压波动中起作用,该关联在HIV感染者中不论是否接受HAART均存在。
研究设计与样本
- 回顾性横断面研究,纳入2000至2016年间某学术眼科中心的400例患者。
- G1为HIV感染且接受HAART者(n=176),G2为HIV感染未接受HAART者(n=48),G3为无HIV对照者(n=176)。
- 采用方差分析(ANOVA)比较平均眼压,多因素线性与逻辑回归评估影响眼压的因素,眼压差异为主要结局指标。
主要发现
- 平均眼压(mmHg):G1 13.7±5.1、G2 13.1±3.6、G3 17.3±3.8,P<.01。
- 回归模型中,CD4计数≤700 cells/mm3使眼压降低2.1 mmHg。
- HIV感染者眼压≤10 mmHg的可能性为对照的7倍。
- CD4计数≤700 cells/mm3者眼压≤10 mmHg的可能性为13倍。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Prior studies have shown an association between human immunodeficiency virus (HIV) and reduced intraocular pressures (IOP). The purpose of this study was to determine if patients with HIV on highly active antiretroviral therapy (HAART) had any difference in their IOP compared with patients without HIV or with HIV who are not on HAART. DESIGN: Retrospective cross-sectional study. METHODS: We included 400 patients from our academic eye center between 2000 and 2016. Group 1 (G1) consisted of patients with HIV on HAART (n = 176), Group 2 (G2) consisted of patients with HIV who were not on HAART (n = 48), and Group 3 (G3) consisted of controls without HIV (n = 176). An analysis of variance (ANOVA) was performed to compare mean IOP values. Multivariate linear and logistic regression models were performed to assess factors impacting IOP. Difference in IOP was the primary outcome being measured. RESULTS: The mean IOPs in mm Hg were 13.7 ± 5.1 (G1), 13.1 ± 3.6 (G2), and 17.3 ± 3.8 (G3), P < .01. In regression modeling, having a CD4 count ≤700 cells/mm3 contributed to a 2.1 mm Hg decrease in IOP. Patients with HIV were 7 times more likely to have an IOP ≤10 mm Hg, and patients with a CD4 count ≤700 cells/mm3 were 13 times more likely to have an IOP ≤10 mm Hg. CONCLUSIONS: Absolute CD4 counts may play a role in IOP fluctuations. This association was found in patients with HIV regardless of whether patients were on HAART.
引用
- Young MT, Melvani RT, Khan FA, et al. Association of Intraocular Pressure With Human Immunodeficiency Virus. Am J Ophthalmol. 2017. PMID: 28147228. doi:10.1016/j.ajo.2017.01.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。