硅油或气体填充治疗黄斑未脱离视网膜脱离后视网膜各层厚度的光学相干断层扫描分割分析
本研究回顾367只硅油填充眼和310只气体填充眼治疗孔源性视网膜脱离,最终分别纳入33只硅油眼和31只气体眼分析。术后6个月硅油组全视网膜及除光感受器层外各层厚度显著下降,气体组无显著变化。硅油组术后6个月和9个月最佳矫正视力显著差于气体组,且神经节细胞层、外丛状层和外核层厚度下降与视力显著相关。
要点
- 硅油填充眼术后6个月全视网膜厚度平均减少23.61±17.01μm,除光感受器层外各层均显著变薄(P<0.001)。
- 气体填充眼术后全视网膜厚度变化仅0.14±7.26μm(P=0.93),各层均无显著下降。
- 硅油组术后6个月和9个月最佳矫正视力显著差于气体组(P=0.003和P=0.004)。
核心结论
- 硅油填充对黄斑未脱离视网膜脱离眼的视网膜厚度减少有显著影响,神经节细胞层、外丛状层和外核层厚度减少与较差视力结局相关性最强。
研究设计与样本
- 回顾性分析367例367只硅油填充眼和310例310只气体填充眼治疗孔源性视网膜脱离,最终纳入硅油组33只眼和气体组31只眼进行分析。
- 采用Spectralis光学相干断层扫描自动视网膜分割方法测量中央1mm区域各视网膜层厚度。
主要发现
- 硅油组(n=33)术后6个月全视网膜厚度平均减少23.61±17.01μm,除光感受器层外各层厚度均显著下降(P<0.001)。
- 气体组(n=31)术后全视网膜厚度平均变化0.14±7.26μm(P=0.93),各视网膜层厚度均无显著下降。
- 硅油组术后6个月和9个月最佳矫正视力均显著差于气体组(分别为P=0.003和P=0.004)。
- 硅油组神经节细胞层、外丛状层和外核层厚度术后减少与最佳矫正视力显著相关(均P<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate and compare the effect of silicone oil and gas on the thickness of all retinal layers in eyes with macula-on retinal detachment (RD). METHODS: Three hundred and sixty-seven eyes of 367 patients who received silicone oil tamponade and 310 eyes of 310 patients who received gas tamponade for the treatment of rhegmatogenous RD were initially reviewed. Automated retinal segmentation method using Spectralis optical coherence tomography was used for analysis. The primary outcome measure was the change in thickness of each retinal layer in the central 1 mm zone (silicone oil vs. gas tamponade). The secondary outcome measure was best-corrected visual acuity at postoperative 6 months and 9 months after primary RD surgery. RESULTS: Eyes in the silicone oil group (n = 33) had a statistically significant decrease in total retinal thickness of 23.61 + 17.01 μm and in the thickness of all retinal layers, except for photoreceptor layer at 6 months after primary RD surgery (P < 0.001). In the gas group (n = 31), the postoperative change in total retinal thickness was only 0.14 ± 7.26 μm (P = 0.93), with no significant decrease in any of the individual retinal layers. Postoperatively, the best-corrected visual acuity in the silicone oil groups was significantly worse than that in the gas group at 6 months and 9 months after RD surgery (P = 0.003 and P = 0.004, respectively). The postoperative decrease of the ganglion cell layer, outer plexiform layer, and outer nuclear layer thicknesses showed significant correlation with best-corrected visual acuity in the silicone oil group (all P < 0.05). CONCLUSION: Silicone oil tamponade had a significant impact on the reduction of retinal thickness and that the reduction of ganglion cell layer, outer plexiform layer, and outer nuclear layer thicknesses showed the strongest correlation with worse visual acuity outcome.
引用
- Lee SH, Han JW, Byeon SH, et al. RETINAL LAYER SEGMENTATION AFTER SILICONE OIL OR GAS TAMPONADE FOR MACULA-ON RETINAL DETACHMENT USING OPTICAL COHERENCE TOMOGRAPHY. Retina. 2018. PMID: 28207606. doi:10.1097/IAE.0000000000001533
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。