文献速递眼底病与葡萄膜炎

光学相干断层扫描定量糖尿病视网膜病变眼内视网膜内硬性渗出

QUANTIFICATION OF INTRARETINAL HARD EXUDATES IN EYES WITH DIABETIC RETINOPATHY BY OPTICAL COHERENCE TOMOGRAPHY.
PubMed 文献 · Retina · 2018-01-01

本研究纳入糖尿病黄斑水肿病例,比较B扫描分割与en face分割测量视网膜内硬性渗出(HE)面积的可重复性。B扫描分割HE面积为1.78±1.37 mm,自动en face分析工具为0.72±0.82 mm,绝对差为1.01±0.64 mm,两种方法总面积相关性极好(r=0.95,P<0.0001)。HE体积为0.06±0.07 mm,与en face HE面积高度相关(r=0.95,P<0.001)。组间可重复性极好,en face法组内相关系数为0.99(95%CI 0.994-0.999),手动分割为0.99(95%CI 0.977-0.997)。结论认为en face分割可可靠定量HE,结果虽持续偏低但与密集OCT所有B扫描穷举分割的HE测量值相关性好。

要点

  • B扫描分割HE面积为1.78±1.37 mm,自动en face工具为0.72±0.82 mm,绝对差1.01±0.64 mm。
  • 两种方法总面积相关性极好(r=0.95,P<0.0001),HE体积与en face面积高度相关(r=0.95,P<0.001)。
  • 组间可重复性极好:en face法ICC 0.99(95%CI 0.994-0.999),手动分割ICC 0.99(95%CI 0.977-0.997)。

核心结论

  • 糖尿病视网膜病变眼内HE定量可通过en face分割可靠进行,en face结果虽持续偏低但与密集OCT所有B扫描穷举分割的HE测量值相关性好。

研究设计与样本

  • 纳入糖尿病黄斑水肿病例,比较B扫描分割与en face分割获得的HE面积,并评估组间可重复性。

主要发现

  • B扫描分割HE面积为1.78±1.37 mm,自动en face分析工具为0.72±0.82 mm,绝对差为1.01±0.64 mm。
  • 两种方法HE总面积相关性极好(r=0.95,P<0.0001)。
  • HE体积为0.06±0.07 mm,与en face HE面积高度相关(r=0.95,P<0.001)。
  • 组间可重复性极好:en face法ICC为0.99(95%CI 0.994-0.999),手动分割ICC为0.99(95%CI 0.977-0.997)。

关键数值与推荐

  • B扫描分割HE面积1.78±1.37 mm vs en face自动分析工具0.72±0.82 mm,绝对差1.01±0.64 mm。
  • HE体积0.06±0.07 mm,与en face HE面积r=0.95(P<0.001)。
  • en face法组间ICC 0.99(95%CI 0.994-0.999),手动分割ICC 0.99(95%CI 0.977-0.997)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the reproducibility of intraretinal hard exudate (HE) quantification from spectral domain optical coherence tomography (SD-OCT) images of eyes with diabetic retinopathy (DR). METHODS: Cases with diabetic macular edema were enrolled. The area of HE obtained by B-scan segmentation was compared with the area obtained by en face segmentation. RESULTS: The mean ± SD for the HE area was 1.78 ± 1.37 mm with B-scan segmentation and 0.72 ± 0.82 mm with the automated en face analysis tool; the absolute difference was 1.01 ± 0.64 mm. There was excellent correlation in total HE area between the two methods (r = 0.95, P < 0.0001). The HE volume was 0.06 ± 0.07 mm. The correlation between HE volume and en face HE area was high (r = 0.95, P < 0.001). Intergrader reproducibility yielded excellent agreement with an intraclass correlation coefficient value of 0.99 (95% CI 0.994-0.999) for the en face approach and 0.99 (95% CI 0.977-0.997) for manual segmentation. CONCLUSION: Quantification of HE in eyes with diabetic retinopathy can be performed reliably using en face segmentation and, though the en face results are consistently lower, correlates well with HE measurements obtained by exhaustive segmentation of all B-scans in dense volume optical coherence tomography (OCT).

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Srinivas S, Nittala MG, Hariri A, et al. QUANTIFICATION OF INTRARETINAL HARD EXUDATES IN EYES WITH DIABETIC RETINOPATHY BY OPTICAL COHERENCE TOMOGRAPHY. Retina. 2018. PMID: 28196059. doi:10.1097/IAE.0000000000001545

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。