文献速递眼底病与葡萄膜炎

采用扫频源光学相干断层扫描评估糖尿病视网膜病变中的脉络膜厚度

CHOROIDAL THICKNESS IN DIABETIC RETINOPATHY ASSESSED WITH SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY.
PubMed 文献 · Retina · 2018-01-01

多中心前瞻性横断面研究纳入50只对照眼和160只糖尿病眼,用扫频源光学相干断层扫描测量脉络膜厚度。增殖性糖尿病视网膜病变眼平均脉络膜厚度(β=-42.9,P=0.022)和中心脉络膜厚度(β=-50.2,P=0.013)较对照眼统计学显著变薄;控制年龄后,糖尿病视网膜病变眼中心脉络膜厚度较无视网膜病变的糖尿病眼显著降低(β=-36.2,P=0.009)。

要点

  • 增殖性糖尿病视网膜病变眼平均及中心脉络膜厚度较对照眼统计学显著变薄。
  • 控制年龄后,糖尿病视网膜病变眼中心脉络膜厚度较无视网膜病变糖尿病眼显著降低。
  • 扫频源光学相干断层扫描可定量评估糖尿病视网膜病变脉络膜厚度变化。

核心结论

  • 扫频源光学相干断层扫描显示增殖性糖尿病视网膜病变眼脉络膜厚度较对照眼显著降低。
  • 在黄斑中心凹区域,糖尿病视网膜病变眼脉络膜似乎比无视网膜病变的糖尿病眼更薄。

研究设计与样本

  • 多中心、前瞻性、横断面研究,纳入糖尿病患者眼和非糖尿病受试者眼,使用扫频源光学相干断层扫描成像。
  • 共纳入50只对照眼和160只糖尿病眼(无糖尿病视网膜病变27只、非增殖性糖尿病视网膜病变51只、非增殖性糖尿病视网膜病变伴糖尿病黄斑水肿61只、增殖性糖尿病视网膜病变21只)。
  • 采用自动软件获取按早期治疗糖尿病视网膜病变研究九分区划分的脉络膜厚度图,平均脉络膜厚度取早期治疗糖尿病视网膜病变研究网格内均值,中心脉络膜厚度取中央1 mm均值。
  • 采用多水平混合线性模型进行分析。

主要发现

  • 增殖性糖尿病视网膜病变眼平均脉络膜厚度较对照眼统计学显著变薄(β=-42.9,P=0.022)。
  • 增殖性糖尿病视网膜病变眼中心脉络膜厚度较对照眼统计学显著变薄(β=-50.2,P=0.013)。
  • 上述差异在调整混杂因素后仍存在。
  • 控制年龄后,糖尿病视网膜病变眼中心脉络膜厚度较无视网膜病变的糖尿病眼显著降低(β=-36.2,P=0.009)。

关键数值与推荐

  • 增殖性糖尿病视网膜病变眼平均脉络膜厚度β=-42.9(P=0.022),中心脉络膜厚度β=-50.2(P=0.013),均较对照眼变薄。
  • 糖尿病视网膜病变眼中心脉络膜厚度较无视网膜病变的糖尿病眼β=-36.2(P=0.009),方向为降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the choroidal thickness (CT) of diabetic eyes (different stages of disease) with controls, using swept-source optical coherence tomography. METHODS: A multicenter, prospective, cross-sectional study of diabetic and nondiabetic subjects using swept-source optical coherence tomography imaging. Choroidal thickness maps, according to the nine Early Treatment Diabetic Retinopathy Study (ETDRS) subfields, were obtained using automated software. Mean CT was calculated as the mean value within the ETDRS grid, and central CT as the mean in the central 1 mm. Diabetic eyes were divided into four groups: no diabetic retinopathy (No DR), nonproliferative DR (NPDR), NPDR with diabetic macular edema (NPDR + DME), and proliferative DR (PDR). Multilevel mixed linear models were performed for analyses. RESULTS: The authors included 50 control and 160 diabetic eyes (n = 27 No DR, n = 51 NPDR, n = 61 NPDR + DME, and n = 21 PDR). Mean CT (ß = -42.9, P = 0.022) and central CT (ß = -50.2, P = 0.013) were statistically significantly thinner in PDR eyes compared with controls, even after adjusting for confounding factors. Controlling for age, DR eyes presented a significantly decreased central CT than diabetic eyes without retinopathy (β = -36.2, P = 0.009). CONCLUSION: Swept-source optical coherence tomography demonstrates a significant reduction of CT in PDR compared with controls. In the foveal region, the choroid appears to be thinner in DR eyes than in diabetic eyes without retinopathy.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Laíns I, Talcott KE, Santos AR, et al. CHOROIDAL THICKNESS IN DIABETIC RETINOPATHY ASSESSED WITH SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY. Retina. 2018. PMID: 28196053. doi:10.1097/IAE.0000000000001516

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。