涵盖中心10°视野的屈光参差性弱视空间与全局感觉抑制映射
本研究纳入26例屈光参差性弱视患者(平均年龄19.15±4.42岁),采用新型双眼分视映射范式评估中心10°视野内的抑制分布,并与传统临床指标及两种心理物理抑制测量进行一致性比较。结果显示新型定量映射技术与眼间视力差(P<0.001)和立体视锐度(P=0.005)均呈良好一致性,且与双眼相位组合任务(P<0.001)和全局运动相干任务(P=0.005)结果一致。结论认为双眼分视抑制映射技术能有效反映屈光参差性弱视的视功能损害,在弱视的微抑制映射测试与治疗方面具有潜力。
要点
- 屈光参差性弱视患者中心10°视野内抑制随亮度调制而变化,正常对照亦如此。
- 新型定量映射技术与眼间视力差(P<0.001)及立体视锐度(P=0.005)一致性良好。
- 映射结果与双眼相位组合(P<0.001)、全局运动相干(P=0.005)两种心理物理方法一致。
核心结论
- 双眼分视抑制映射技术是反映屈光参差性弱视患者视功能损害的有效方法,在弱视的微抑制映射测试与治疗方面具有潜力。
研究设计与样本
- 研究纳入26例屈光参差性弱视患者,平均年龄19.15±4.42岁,采用标准临床视功能测量与新型定量映射技术进行评估。
- 另采用双眼全局运动相干任务和双眼相位组合任务两种心理物理眼间抑制测量,并通过在正常眼前放置中性密度滤光片实现亮度降低。
主要发现
- 屈光参差性弱视患者及正常对照的中心10°视野内抑制随平均亮度调制而变化。
- 通过模拟与消除眼间抑制,研究识别出一种有效反映屈光参差性弱视抑制分布的新方法。
- 新型定量映射技术与眼间视力差(P<0.001)及立体视锐度(P=0.005)两种传统临床指标一致性良好。
- 双眼分视映射范式测得的眼间抑制结果与双眼相位组合任务(P<0.001)及全局运动相干任务(P=0.005)结果一致性良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We investigate the efficacy of a novel dichoptic mapping paradigm in evaluating visual function of anisometropic amblyopes. METHODS: Using standard clinical measures of visual function (visual acuity, stereo acuity, Bagolini lenses, and neutral density filters) and a novel quantitative mapping technique, 26 patients with anisometropic amblyopia (mean age = 19.15 ± 4.42 years) were assessed. Two additional psychophysical interocular suppression measurements were tested with dichoptic global motion coherence and binocular phase combination tasks. Luminance reduction was achieved by placing neutral density filters in front of the normal eye. RESULTS: Our study revealed that suppression changes across the central 10° visual field by mean luminance modulation in amblyopes as well as normal controls. Using simulation and an elimination of interocular suppression, we identified a novel method to effectively reflect the distribution of suppression in anisometropic amblyopia. Additionally, the new quantitative mapping technique was in good agreement with conventional clinical measures, such as interocular acuity difference (P < 0.001) and stereo acuity (P = 0.005). There was a good consistency between the results of interocular suppression with dichoptic mapping paradigm and the results of the other two psychophysical methods (suppression mapping versus binocular phase combination, P < 0.001; suppression mapping versus global motion coherence, P = 0.005). CONCLUSIONS: The dichoptic suppression mapping technique is an effective method to represent impaired visual function in patients with anisometropic amblyopia. It offers a potential in "micro-"antisuppression mapping tests and therapies for amblyopia.
引用
- Li J, Li J, Chen Z, et al. Spatial and Global Sensory Suppression Mapping Encompassing the Central 10° Field in Anisometropic Amblyopia. Invest Ophthalmol Vis Sci. 2017. PMID: 28122090. doi:10.1167/iovs.16-20298
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。