文献速递白内障与屈光手术

方形边缘聚甲基丙烯酸甲酯人工晶状体长期减少后囊膜混浊:随机对照研究

Long-term Posterior Capsule Opacification Reduction with Square-Edge Polymethylmethacrylate Intraocular Lens: Randomized Controlled Study.
PubMed 文献 · Ophthalmology · 2017-01-05

这项前瞻性随机对照对侧眼临床研究纳入94例拟行双侧超声乳化患者,一眼植入方形边缘聚甲基丙烯酸甲酯(SE-PMMA)人工晶状体,对侧眼植入圆形边缘PMMA(RE-PMMA,A组46例)或方形边缘疏水性丙烯酸酯(SE-Acrylic,B组48例)。9年随访时,A组SE-PMMA眼后囊膜混浊评分在所有随访点均显著低于对侧RE-PMMA眼,Nd:YAG后囊切开率2%对37%(P<0.001);B组SE-PMMA眼在除1年和3年外的随访点PCO评分低于对侧SE-Acrylic眼,9年Nd:YAG后囊切开率4%对10%(P=0.435)。结论提示方形光学边缘的PMMA人工晶状体设计改进可能显著减少发展中国家视力损害性 secondary membrane 的负担。

要点

  • A组9年Nd:YAG后囊切开率SE-PMMA眼2% vs RE-PMMA眼37%(P<0.001)。
  • B组9年Nd:YAG后囊切开率SE-PMMA眼4% vs SE-Acrylic眼10%(P=0.435)。
  • A组SE-PMMA眼PCO评分在所有随访点均显著低于对侧RE-PMMA眼(P<0.05)。

核心结论

  • 这项前瞻性9年对侧眼对照研究提示,廉价的PMMA人工晶状体设计改进——方形光学边缘——可能显著减少发展中国家视力损害性 secondary membrane 的负担。

研究设计与样本

  • 前瞻性、随机、对照的对侧眼临床研究,纳入94例计划行双侧超声乳化患者,一眼植入SE-PMMA人工晶状体。
  • A组46例对侧眼植入RE-PMMA人工晶状体,B组48例对侧眼植入SE-Acrylic人工晶状体;随机化决定分组及第一只手术眼植入何种人工晶状体。
  • 采用后囊膜混浊评估(EPCO)图像分析软件,对术后前5年每年及第9年获取的标准高分辨率后照法照片进行PCO密度客观分级。

主要发现

  • A组9年随访完成率72%,B组63%。
  • A组SE-PMMA眼平均PCO评分在所有随访点均显著低于对侧RE-PMMA眼(P<0.05)。
  • B组SE-PMMA眼平均PCO评分在除1年和3年随访外的所有随访点均统计学低于对侧SE-Acrylic眼。
  • 9年Nd:YAG后囊切开率:A组SE-PMMA眼2% vs RE-PMMA眼37%(P<0.001);B组SE-PMMA眼4% vs SE-Acrylic眼10%(P=0.435)。
  • RE-PMMA的PCO发生率未出现平台期,在整个9年研究期间持续增加。

关键数值与推荐

  • A组9年Nd:YAG后囊切开率SE-PMMA眼2% vs RE-PMMA眼37%(P<0.001)。
  • B组9年Nd:YAG后囊切开率SE-PMMA眼4% vs SE-Acrylic眼10%(P=0.435)。

临床怎么用

  • 原文结论提示,方形光学边缘的PMMA人工晶状体设计改进可能显著减少发展中国家视力损害性 secondary membrane 的负担。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To objectively assess the long-term posterior capsule opacification (PCO) and neodymium-doped yttrium aluminium garnet (Nd:YAG) capsulotomy rate of a square-edge (SE) polymethylmethacrylate (PMMA) intraocular lens (IOL) modification in comparison with a round-edge (RE) PMMA IOL or an SE hydrophobic acrylic IOL (SE-Acrylic). DESIGN: Prospective, randomized, controlled fellow eye clinical study. PARTICIPANTS: Ninety-four patients scheduled for bilateral phacoemulsification had an SE-PMMA IOL implanted in 1 eye. An RE-PMMA IOL was implanted in the fellow eye in 46 patients (group A), and an SE-Acrylic IOL was implanted in the fellow eye in 48 patients (group B). Randomization was used to determine group assignment and which IOL was implanted in the first eye to undergo surgery. METHODS: Evaluation of Posterior Capsule Opacification (EPCO) image analysis software was used to objectively grade PCO density from standardized, high-resolution retroillumination photographs obtained annually for the first 5 postoperative years and at year 9. MAIN OUTCOME MEASURES: The PCO scores and Nd:YAG capsulotomy rate. RESULTS: Nine-year follow-up was achieved by 72% from group A and 63% from group B. In group A, the mean PCO score was significantly lower in the SE-PMMA IOL eyes compared with the contralateral RE-PMMA eyes at all follow-up visits (P < 0.05). In group B, the mean PCO score was statistically lower in the SE-PMMA IOL eyes compared with the contralateral SE-Acrylic IOL eyes at all but the 1- and 3-year follow-up visits. Nine-year Nd:YAG capsulotomy rates were 2% for SE-PMMA IOLs versus 37% for RE-PMMA IOLs in group A (P < 0.001), and 4% for SE-PMMA IOLs versus 10% for SE-Acrylic IOLs in group B (P = 0.435). The RE-PMMA PCO rate did not plateau and continued to increase throughout the 9-year study period. CONCLUSIONS: This prospective, 9-year fellow eye comparison study suggests that an inexpensive PMMA IOL design modification-a squared optic edge-could significantly reduce the burden of vision-impairing secondary membrane in developing countries.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Haripriya A, Chang DF, Vijayakumar B, et al. Long-term Posterior Capsule Opacification Reduction with Square-Edge Polymethylmethacrylate Intraocular Lens: Randomized Controlled Study. Ophthalmology. 2017. PMID: 28065436. doi:10.1016/j.ophtha.2016.11.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。