青光眼与高眼压眼及正常眼中浅层血管密度与筛板前血流指数的鉴别能力
本研究评估光学相干断层扫描血管成像参数——视盘周围浅层视网膜血管密度与筛板前血流指数(PLFI)——区分原发性开角型青光眼(POAG)和高眼压症(OH)与正常眼的能力。在105名受试者的一只眼中检测血管密度、PLFI、视野平均偏差、视盘周围视网膜神经纤维层厚度(cpNFLT)及神经节细胞复合体整体丢失体积。结果显示POAG眼血管密度(P<0.001)和单位面积PLFI(PLFI/UA;P=0.020)显著低于正常眼;OH眼血管密度显著降低(P=0.018),而PLFI/UA、整体丢失体积和cpNFLT未受影响。血管密度区分青光眼和OH与正常眼的AUC分别为0.832和0.724,显著优于PLFI/UA的0.662(P=0.002)和0.569(P=0.038)。血管密度和PLFI/UA区分POAG与正常眼的能力劣于整体丢失体积(P=0.006和<0.0001)和cpNFLT(P=0.055和P<0.0001)。结论认为青光眼眼血管密度和PLFI/UA显著下降,血管密度在区分青光眼和OH与正常眼方面比PLFI/UA更有效。
要点
- POAG眼血管密度(P<0.001)和PLFI/UA(P=0.020)显著低于正常眼。
- OH眼血管密度显著降低(P=0.018),但PLFI/UA、整体丢失体积和cpNFLT未受影响。
- 血管密度区分青光眼和OH与正常眼的AUC分别为0.832和0.724,优于PLFI/UA的0.662(P=0.002)和0.569(P=0.038)。
核心结论
- 青光眼眼血管密度和PLFI/UA显著下降。
- 血管密度在区分青光眼和OH与正常眼方面比PLFI/UA更有效。
研究设计与样本
- 评估105名POAG、OH和正常眼受试者的一只眼,基于受试者工作特征曲线下面积(AUC)和多重比较评估各参数的鉴别能力。
主要发现
- POAG眼血管密度(P<0.001)和PLFI/UA(P=0.020)显著低于正常眼。
- OH眼血管密度显著降低(P=0.018),而PLFI/UA、整体丢失体积和cpNFLT未受影响。
- 血管密度区分青光眼和OH与正常眼的AUC分别为0.832和0.724,显著优于PLFI/UA的0.662(P=0.002)和0.569(P=0.038)。
- 血管密度和PLFI/UA区分POAG与正常眼的能力劣于整体丢失体积(P=0.006和<0.0001)和cpNFLT(P=0.055和P<0.0001)。
关键数值与推荐
- 血管密度区分青光眼与正常眼的AUC为0.832。
- 血管密度区分OH与正常眼的AUC为0.724。
- PLFI/UA区分青光眼与正常眼的AUC为0.662(P=0.002)。
- PLFI/UA区分OH与正常眼的AUC为0.569(P=0.038)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We evaluate the ability of optical coherence tomography angiography parameters, such as the peripapillary vessel density of the superficial retina and prelaminar flow index of the optic disc (PLFI), to differentiate primary open-angle glaucoma (POAG) and ocular hypertension (OH) from normal eyes. METHODS: The vessel density, PLFI, mean deviation of the visual field, circumpapillary retinal nerve fiber layer thickness (cpNFLT), and global loss volume of the ganglion cell complex were evaluated in one eye of 105 subjects with POAG and OH and normal eyes. The discriminatory powers of these parameters were evaluated based on the area under the curve (AUC) of the receiver operation characteristic curve and multiple comparisons. RESULTS: The vessel density (P < 0.001) and PLFI/unit area (PLFI/UA; P = 0.020) in eyes with POAG were significantly less than in normal eyes. The vessel density in eyes with OH was significantly (P = 0.018) reduced, whereas the PLFI/UA, global loss volume and cpNFLT were unaffected. The AUCs of the vessel density to discriminate glaucoma and OH from normal eyes were 0.832 and 0.724, respectively, and were significantly better than the PLFI/UA, in which the AUCs were 0.662 (P = 0.002) and 0.569 (P = 0.038), respectively. The powers of the vessel density and PLFI/UA to discriminate POAG from normal eyes were inferior to the global loss volume (P = 0.006 and <0.0001) and cpNFLT (P = 0.055 and P < 0.0001, respectively). CONCLUSIONS: The vessel density and PLFI/UA decreased significantly in glaucomatous eyes. The vessel density was more efficient than the PLFI/UA for differentiating glaucoma and OH from normal eyes.
引用
- Chihara E, Dimitrova G, Amano H, et al. Discriminatory Power of Superficial Vessel Density and Prelaminar Vascular Flow Index in Eyes With Glaucoma and Ocular Hypertension and Normal Eyes. Invest Ophthalmol Vis Sci. 2017. PMID: 28134965. doi:10.1167/iovs.16-20709
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。