文献速递青光眼眼底病与葡萄膜炎

老年人群中视盘周围视网膜神经纤维层厚度检测青光眼的诊断性能:ALIENOR研究

Diagnostic Performance of Peripapillary Retinal Nerve Fiber Layer Thickness for Detection of Glaucoma in an Elderly Population: The ALIENOR Study.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2016-01-01

ALIENOR研究纳入2009至2010年624名74岁及以上老年人,行视盘彩色照相和SD-OCT检查,按国际标准诊断青光眼,比较视盘周围RNFL厚度在青光眼与对照者间的诊断准确性。532名数据完整者中492名为对照、40名为青光眼,平均RNFL厚度两组差异有统计学意义(对照88.7±12.2 μm vs 青光眼65.4±14.4 μm,P<0.001)。黄斑颞下和颞上RNFLT的AUC较高,颞上RNFLT的DOR最高(25.31),作者认为SD-OCT RNFL参数可为老年人群青光眼筛查提供有价值信息。

要点

  • 平均RNFL厚度青光眼组65.4±14.4 μm,低于对照组的88.7±12.2 μm(P<0.001)。
  • 平均RNFLT的AUC为0.895,颞下为0.874,颞上为0.868。
  • 颞上RNFLT的DOR为25.31(LR+ 4.65,LR- 0.18),平均RNFLT的DOR为24.80(LR+ 6.36,LR- 0.26)。

核心结论

  • SD-OCT测量的RNFL参数可能为老年一般人群青光眼筛查策略提供有价值的信息。

研究设计与样本

  • ALIENOR(Antioxydants, Lipides Essentiels, Nutrition et Maladies Oculaires)是一项基于人群的研究。
  • 2009至2010年共624名74岁及以上受试者接受完整眼科检查,包括视盘彩色照相及黄斑和视神经头的SD-OCT检查。
  • 青光眼诊断依据视神经头视网膜照相和国际流行病学与地理眼科学会标准。
  • 532名受试者数据完整,其中492名为对照、40名为青光眼;平均年龄82.1±4.2岁。

主要发现

  • 平均RNFLT在两组间差异有统计学意义:对照组88.7±12.2 μm vs 青光眼组65.4±14.4 μm,P<0.001。
  • AUC最高的参数为平均RNFLT(0.895)、颞下RNFLT(0.874)和颞上RNFLT(0.868)。
  • 颞上RNFLT的DOR最高(25.31;LR+ 4.65;LR- 0.18),其次为平均RNFLT(DOR 24.80;LR+ 6.36;LR- 0.26)。
  • 使用仪器自带正常值数据库、以至少一项参数异常(P<0.05)为标准时,DOR增至31.03(LR+ 1.75;LR- 0.06)。

关键数值与推荐

  • 青光眼诊断采用视神经头视网膜照相及国际流行病学与地理眼科学会标准。
  • 诊断准确性指标包括受试者工作特征曲线下面积(AUC)、阳性与阴性似然比(LR+/LR-)及诊断比值比(DOR)。

临床怎么用

  • 作者认为SD-OCT的RNFL参数可能为老年一般人群青光眼筛查策略提供有价值的信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess diagnostic accuracy of spectral-domain optical coherence tomography (SD-OCT) to discriminate glaucoma and control subjects in an elderly population. METHODS: The antioxidants, essential lipids, nutrition and ocular maladies study (ALIENOR: "Antioxydants, Lipides Essentiels, Nutrition et Maladies Oculaires") is a population-based study. From 2009 to 2010, a total of 624 subjects, aged 74 years or older underwent a complete eye examination, including optic disc color photography and SD-OCT examination of the macula and the optic nerve head. Glaucoma diagnosis was made using retinophotography of the optic nerve head and International Society for Epidemiologic and Geographical Ophthalmology criteria. Average and sectorial peripapillary retinal nerve fiber layer thicknesses (RNFLT) were compared between glaucoma and control subjects using area under the receiver operating characteristic curves (AUC), positive and negative likelihood ratios (LR+/LR-), and diagnostic odds ratios (DOR). RESULTS: A total of 532 subjects had complete data, 492 were classified as controls and 40 were classified as glaucoma. Mean age was 82.1 ± 4.2 years and average RNFLT was significantly different between both groups (controls: 88.7 ± 12.2 μm, glaucoma: 65.4 ± 14.4 μm, P < 0.001). Highest AUC values were observed for average (0.895), temporal-inferior (0.874), and temporal-superior (0.868) RNFLT. Temporal-superior RNFLT had the highest DOR (25.31; LR+, 4.65; LR-, 0.18), followed by average RNFLT (DOR: 24.80; LR+, 6.36; LR-, 0.26). When using the normative database provided by the machine, DOR increased to 31.03 (LR+, 1.75; LR-, 0.06) if at least one parameter was considered abnormal (at P < 0.05). CONCLUSIONS: Parameters of SD-OCT RNFL may provide valuable information in a screening strategy to improve glaucoma detection in a general population of elderly people.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Schweitzer C, Korobelnik JF, Le Goff M, et al. Diagnostic Performance of Peripapillary Retinal Nerve Fiber Layer Thickness for Detection of Glaucoma in an Elderly Population: The ALIENOR Study. Invest Ophthalmol Vis Sci. 2016. PMID: 27802518. doi:10.1167/iovs.16-20104

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。