比较六氟化硫20%与100%空气前房填充的后弹力层内皮角膜移植术一年结局
本回顾性研究纳入854例连续后弹力层内皮角膜移植术(DMEK),按前房填充物分为六氟化硫20%(SF6 20%)组105例(12.3%)与100%空气组749例(87.7%),比较术后1年临床结局与并发症。两组在眼压、最佳矫正视力、内皮细胞密度和中央角膜厚度各随访时间点均无统计学显著差异(p≥0.05),但SF6 20%组需再次注气的植片脱离率显著更低(p<0.001)。
要点
- SF6 20%前房填充组需再次注气的植片脱离率显著低于100%空气组(p<0.001)。
- 两组术后1、3、6、12个月眼压、最佳矫正视力、内皮细胞密度和中央角膜厚度均无统计学显著差异(p≥0.05)。
- SF6 20%前房填充在术后第一年内似乎不影响DMEK临床结局。
核心结论
- SF6 20%前房填充在术后第一年内似乎不负面影响DMEK手术临床结局,且显著降低再次注气率。
研究设计与样本
- 回顾性复习1112例连续DMEK记录,按术中前房填充物(SF6 20% vs 100%空气)分组,最终纳入854例。
主要发现
- SF6 20%组105例(12.3%),100%空气组749例(87.7%)。
- 术后1、3、6、12个月眼压、最佳矫正视力、内皮细胞密度和中央角膜厚度两组相当,无统计学显著差异(p≥0.05)。
- 需再次注气的植片脱离率SF6 20%组显著低于100%空气组(p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate 1-year clinical outcome and complication rates following Descemet membrane endothelial keratoplasty (DMEK) with sulfur hexafluoride 20% (SF620%) anterior chamber tamponade compared with conventionally used 100% air for primary graft attachment during DMEK surgery. METHODS: Records of 1112 consecutive DMEKs were reviewed retrospectively and grouped by anterior chamber tamponade used during DMEK surgery (SF620% vs 100% air). Outcome measures included intraocular pressure (IOP), best spectacle-corrected visual acuity (BSCVA), endothelial cell density (ECD) and central corneal thickness (CCT) at 1, 3, 6 and 12 months after DMEK surgery. Complication rates were assessed, including intraoperative and postoperative complications, and graft detachment rate requiring rebubbling. RESULTS: A total of 854 cases were included in this study. In 105 cases (12.3%), DMEK was performed with SF620%, and in 749 cases (87.7%) 100% air was used for anterior chamber tamponade. Outcome results for IOP, BSCVA, ECD and CCT at all follow-up time points were comparable for both anterior chamber tamponade groups without statistical significant differences (p≥0.05), but graft detachment rate requiring rebubbling was significantly lower in the SF620% group (p<0.001). CONCLUSION: Whereas SF620% anterior chamber tamponade does not seem to negatively affect the clinical outcome of DMEK surgery within the first postoperative year, use of SF620% significantly reduces the rate of rebubblings.
引用
- Schaub F, Enders P, Snijders K, et al. One-year outcome after Descemet membrane endothelial keratoplasty (DMEK) comparing sulfur hexafluoride (SF6) 20% versus 100% air for anterior chamber tamponade. Br J Ophthalmol. 2016. PMID: 27836829. doi:10.1136/bjophthalmol-2016-309653
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。