正常眼健康人群中不同种族间Bruch膜开口最小边缘宽度的比较
本横断面研究纳入269只正常视神经眼(148名参与者),比较非洲裔与欧洲裔人群的Bruch膜开口最小边缘宽度(BMO-MRW)。校正年龄、性别和BMO面积后,全球及区域BMO-MRW在种族间均无统计学显著差异(P=.60)。作者认为非洲裔患者使用BMO-MRW可能不需要种族特异性正常参考数据。
要点
- 校正年龄、性别和BMO面积后,非洲裔与欧洲裔的全球平均BMO-MRW无统计学显著差异(P=.60)。
- 区域BMO-MRW在粗模型中存在种族差异,但校正后差异均无统计学显著性。
- 作者认为非洲裔患者使用BMO-MRW可能不需要种族特异性正常参考数据。
核心结论
- 非洲裔与欧洲裔正常眼健康人群的BMO-MRW无统计学显著差异,种族特异性正常参考数据可能并非非洲裔患者使用BMO-MRW所必需。
研究设计与样本
- 横断面研究,纳入在零售基础眼科诊所接受综合眼科检查、符合至少一项青光眼高危标准(非洲裔年龄≥40岁、欧洲裔年龄≥50岁、糖尿病、青光眼家族史和/或已确诊青光眼)且检查视神经正常者,共269只眼(148名参与者),行视神经乳头谱域光学相干断层扫描(24条径向扫描)。
主要发现
- 全球平均BMO-MRW随年龄增长而下降。
- 校正年龄、性别和BMO面积后,全球平均BMO-MRW的种族间差异无统计学显著性(P=.60)。
- 粗模型中,非洲裔眼在颞侧、颞上及鼻侧区域的平均BMO-MRW较低,在颞下、鼻上及鼻下区域较高;校正模型中这些差异均无统计学显著性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To examine if racial differences in Bruch's membrane opening minimum rim width (BMO-MRW) in spectral-domain optical coherence tomography (SDOCT) exist, specifically between people of African descent (AD) and European descent (ED) in normal ocular health. DESIGN: Cross-sectional study. METHODS: Patients presenting for a comprehensive eye examination at retail-based primary eye clinics were enrolled based on ≥1 of the following at-risk criteria for glaucoma: AD aged ≥40 years, ED aged ≥50 years, diabetes, family history of glaucoma, and/or pre-existing diagnosis of glaucoma. Participants with normal optic nerves on examination received SDOCT of the optic nerve head (24 radial scans). Global and regional (temporal, superotemporal, inferotemporal, nasal, superonasal, and inferonasal) BMO-MRW were measured and compared by race using generalized estimating equations. Models were adjusted for age, sex, and BMO area. RESULTS: SDOCT scans from 269 eyes (148 participants) were included in the analysis. Mean global BMO-MRW declined as age increased. After adjusting for age, sex, and BMO area, there was not a statistically significant difference in mean global BMO-MRW by race (P = .60). Regionally, the mean BMO-MRW was lower in the crude model among AD eyes in the temporal, superotemporal, and nasal regions and higher in the inferotemporal, superonasal, and inferonasal regions. However, in the adjusted model, these differences were not statistically significant. CONCLUSIONS: BMO-MRW was not statistically different between those of AD and ED. Race-specific normative data may not be necessary for the deployment of BMO-MRW in AD patients.
引用
- Rhodes LA, Huisingh CE, Quinn AE, et al. Comparison of Bruch's Membrane Opening Minimum Rim Width Among Those With Normal Ocular Health by Race. Am J Ophthalmol. 2016. PMID: 27825982. doi:10.1016/j.ajo.2016.10.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。