文献速递青光眼

使用偏振敏感光学相干断层扫描定量评估滤过泡的相位延迟

Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2016-01-01

本研究采用偏振敏感光学相干断层扫描(PS-OCT)对22例患者22个滤过泡连续观察4个月,并对既往122例患者153个滤过泡的数据进行横断面再评估,发现术后1个月相位延迟值升高先于滤过泡功能恶化,且与4个月时滤过泡功能显著相关,横断面定量相位延迟值与滤过泡功能高度相关(β=0.770,P<0.001)。

要点

  • 术后2周内所有滤过泡相位延迟值低且功能良好,术后1个月相位延迟值显著升高而滤过泡功能仍良好。
  • 术后1个月相位延迟值与术后4个月滤过泡功能显著相关。
  • 术后1个月高相位延迟值滤过泡中55.6%随后失去功能,低相位延迟值者仅7.7%出现滤过泡失败。

核心结论

  • 相位延迟值升高先于滤过泡功能恶化,相位延迟变化可能为术后早期滤过泡功能提供预后指标。

研究设计与样本

  • 连续纳入22例患者22个滤过泡,术后连续观察4个月,用PS-OCT测量相位延迟并定量分析其与基于眼压和用药的滤过泡功能的关系。
  • 对既往122例患者153个滤过泡的数据集进行横断面再评估。

主要发现

  • 连续测量中,所有滤过泡直至术后2周均显示低相位延迟值和良好滤过泡功能。
  • 术后1个月相位延迟值显著升高,而滤过泡功能仍良好。
  • 术后1个月相位延迟值与术后4个月滤过泡功能显著相关。
  • 术后1个月高相位延迟值滤过泡中55.6%随后失去功能,低相位延迟值滤过泡中仅7.7%出现滤过泡失败。
  • 横断面再评估中,定量评估的相位延迟值与滤过泡功能高度相关(β=0.770,P<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Polarization-sensitive optical coherence tomography (PS-OCT) can detect and evaluate scar fibrosis of the filtering blebs after glaucoma surgery. Although the change in phase retardation reportedly reflects bleb function, quantitative assessment of phase retardation in ocular tissues has not been conducted. We aimed to establish quantitative methods to investigate changes in phase retardation in the blebs after surgery using PS-OCT. METHODS: Twenty-two blebs of 22 patients who had undergone glaucoma filtration surgery were consecutively examined for 4 months. Phase retardation was measured by PS-OCT and quantitatively analyzed to evaluate its relationship with bleb function based on intraocular pressure and medication use. Cross-sectional re-evaluation was also performed for a previous data set of 153 blebs of 122 patients. RESULTS: In consecutive measurements, all blebs showed a low phase retardation value and good bleb function until 2 weeks. One month postoperatively, the phase retardation value was significantly increased, whereas bleb function was still good. The phase retardation value at 1 month postoperatively was significantly correlated with bleb function at 4 months postoperatively. While 55.6% of blebs with a high phase retardation value at 1 month subsequently lost function, only 7.7% with a low phase retardation value had bleb failure. In the cross-sectional re-evaluation, the quantitatively evaluated phase retardation value was highly correlated with bleb function (β = 0.770, P < 0.001). CONCLUSIONS: An increase in phase retardation preceded deterioration of bleb function. The change in phase retardation may provide a prognostic metric for bleb function in the early stage after surgery.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Fukuda S, Fujita A, Kasaragod D, et al. Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography. Invest Ophthalmol Vis Sci. 2016. PMID: 27802522. doi:10.1167/iovs.16-19548

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。