文献速递眼底病与葡萄膜炎

宽视野正面扫频源OCT与常规多模态成像检测网状假性玻璃膜疣的比较

Comparison between Widefield En Face Swept-Source OCT and Conventional Multimodal Imaging for the Detection of Reticular Pseudodrusen.
PubMed 文献 · Ophthalmology · 2016-11-14

该横断面研究前瞻性纳入非渗出性年龄相关性黄斑变性患眼,比较12×12-mm宽视野正面扫频源OCT与彩色、眼底自发荧光及红外反射成像检测网状假性玻璃膜疣/视网膜下玻璃膜疣样沉积物的能力。共评估307眼(209例患者),两种方法检测一致性为83%,检出差异无统计学意义(P=0.21)。作者结论认为四种成像方式联合检测最佳,但单用宽视野正面扫频源OCT至少不劣于常规成像。

要点

  • 宽视野正面扫频源OCT与常规多模态成像检测RPD/SDD的一致性为83%,检出差异无统计学意义(P=0.21)。
  • 扫频源OCT检测RPD/SDD的敏感度为83%,常规成像为75%。
  • 单用扫频源OCT会漏检10%的RPD/SDD病例,单用常规成像会漏检14%。

核心结论

  • 四种成像方式联合使用为检测RPD/SDD的最佳策略;单用宽视野正面扫频源OCT层成像检测RPD/SDD至少不劣于常规成像。

研究设计与样本

  • 横断面研究,前瞻性纳入在Bascom Palmer Eye Institute参加扫频源OCT成像研究的非渗出性年龄相关性黄斑变性患者。
  • 共307眼(209例患者)被评估RPD/SDD的存在或缺失;同日行彩色、眼底自发荧光、红外反射眼底成像及原型Zeiss 100 kHz扫频源OCT成像。
  • 两名设盲评估者分别评估常规多模态图像及同一容积数据集衍生的4种扫频源OCT正面图像上RPD/SDD的存在、缺失或不确定。

主要发现

  • 扫频源OCT与多模态成像检测RPD/SDD的一致性为83%。
  • 两种成像方式检测RPD/SDD的差异无统计学意义(P=0.21)。
  • 扫频源OCT检测RPD/SDD的敏感度为83%,常规成像的敏感度为75%。
  • 单用扫频源OCT成像会漏检10%的RPD/SDD病例,单用常规成像会漏检14%的RPD/SDD病例。
  • 总体分级揭盲后评估者重新评估常规多模态图像与宽视野扫频源OCT正面图像,52例中48例回顾性确认存在RPD/SDD。

关键数值与推荐

  • 扫频源OCT与多模态成像检测RPD/SDD的一致性为83%。
  • 扫频源OCT检测RPD/SDD的敏感度为83%,常规成像为75%。
  • 单用扫频源OCT漏检10%的RPD/SDD病例,单用常规成像漏检14%。
  • 两种成像方式检出RPD/SDD的差异无统计学意义(P=0.21)。

临床怎么用

  • 作者结论认为四种成像方式联合使用为检测RPD/SDD的最佳策略。
  • 作者结论认为单用宽视野正面扫频源OCT层成像检测RPD/SDD至少不劣于常规成像。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The ability to detect reticular pseudodrusen (RPD)/subretinal drusenoid deposits (SDDs) using 12×12-mm widefield en face swept-source optical coherence tomography (SS-OCT) imaging was compared with conventional multimodal imaging (color, fundus autofluorescence (FAF), and infrared reflectance [IR] imaging) in eyes with nonexudative age-related macular degeneration (AMD). DESIGN: Cross-sectional study. PARTICIPANTS: Patients with nonexudative AMD were prospectively enrolled in an SS-OCT imaging study at the Bascom Palmer Eye Institute. METHODS: On the same day, all participants underwent color, FAF, and IR fundus imaging, as well as imaging with a prototype Zeiss 100 kHz SS-OCT instrument (Carl Zeiss Meditec Inc, Dublin, CA). Two masked graders assessed the presence, absence, or uncertainty of RPD/SDDs on conventional multimodal images and separately on 4 different SS-OCT en face images derived from the same volumetric dataset. The results from grading the conventional images and the SS-OCT en face images were compared. MAIN OUTCOME MEASURES: Agreement in the detection of RPD/SDDs using different imaging modalities. RESULTS: A total of 307 eyes (209 patients) were graded for the presence or absence of RPD/SDDs. The agreement between SS-OCT and multimodal imaging was 83%. The difference in RPD/SDD detection with either image modality was not statistically significant (P = 0.21). The sensitivity of SS-OCT in RPD/SDD detection was 83%, and when using conventional imaging, the sensitivity was 75%. When using SS-OCT imaging alone, 10% of RPD/SDD cases would be missed, and when using conventional imaging alone, 14% of RPD/SDD cases would be missed. The presence of RPD/SDD was confirmed retrospectively in 48 of 52 cases once the overall grading was unmasked and the graders reevaluated the conventional multimodal images and the widefield SS-OCT en face images. CONCLUSIONS: All 4 imaging modalities used together provided the best strategy for the detection of RPD/SDDs. However, when using widefield en face SS-OCT slab imaging alone, the detection of RPD/SDDs was at least as good as conventional imaging.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Schaal KB, Legarreta AD, Feuer WJ, et al. Comparison between Widefield En Face Swept-Source OCT and Conventional Multimodal Imaging for the Detection of Reticular Pseudodrusen. Ophthalmology. 2016. PMID: 27856030. doi:10.1016/j.ophtha.2016.10.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。