脉络膜厚度影响年龄相关性黄斑变性所致地图样萎缩眼的近红外反射强度
这项横断面研究纳入104例非新生血管性年龄相关性黄斑变性继发地图样萎缩患眼,评估视网膜与脉络膜厚度对近红外反射成像的影响。结果显示地图样萎缩区在近红外上多为高反射(88眼,85%),黄斑中心凹下脉络膜厚度与近红外平均灰度值存在统计学显著相关(r=0.590;r²=0.348;P<0.00001),而黄斑中心凹视网膜厚度无显著相关(P=0.464)。作者认为脉络膜厚度变化似乎影响地图样萎缩区的近红外强度,可能影响图像判读。
要点
- 104眼中地图样萎缩区近红外表现:高反射88眼(85%)、等反射13眼(12%)、低反射3眼(3%)。
- 黄斑中心凹下脉络膜厚度均值172.6 μm(SD ±114.7),与近红外平均强度线性回归显著(r=0.590;r²=0.348;P<0.00001)。
- 黄斑中心凹视网膜厚度均值101.5 μm(SD ±54),与近红外平均强度无显著关系(P=0.464)。
核心结论
- 脉络膜厚度变化似乎影响地图样萎缩区的近红外反射强度,并可能影响图像判读。
- 认识这一关系可能提供关于脉络膜厚度的有用信息。
研究设计与样本
- 横断面研究,回顾临床记录与多模态影像数据,纳入104例患者的104只非新生血管性年龄相关性黄斑变性继发地图样萎缩眼。
- 影像模态包括彩色眼底照相、眼底自发荧光、近红外扫描激光检眼镜和结构频域光学相干断层扫描(SD-OCT)。
- 由两名独立阅片者测量黄斑中心凹视网膜厚度和黄斑中心凹下脉络膜厚度;地图样萎缩区近红外强度主观分级为高反射、等反射或低反射,并用ImageJ计算各萎缩区平均灰度值进行客观评估。
- 采用线性回归分析建模平均近红外灰度值与视网膜厚度、脉络膜厚度的关系。
主要发现
- 纳入患者平均年龄81.3岁(SD ±8.3)。
- 地图样萎缩区近红外表现:高反射88眼(85%),等反射13眼(12%),低反射3眼(3%)。
- 黄斑中心凹视网膜厚度均值101.5 μm(SD ±54),与平均近红外强度无显著关系(P=0.464)。
- 黄斑中心凹下脉络膜厚度均值172.6 μm(SD ±114.7),在线性回归分析中与平均近红外强度呈统计学显著关系(r=0.590;r²=0.348;P<0.00001)。
关键数值与推荐
- 地图样萎缩区近红外主观分级:高反射88眼(85%)、等反射13眼(12%)、低反射3眼(3%)。
- 黄斑中心凹下脉络膜厚度均值172.6 μm(SD ±114.7)与平均近红外强度线性回归:r=0.590;r²=0.348;P<0.00001。
- 黄斑中心凹视网膜厚度均值101.5 μm(SD ±54)与平均近红外强度:P=0.464。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the effects of retinal and choroidal thickness on near-infrared reflectance (NIR) scanning laser ophthalmoscopy in eyes with geographic atrophy (GA) secondary to non-neovascular age-related macular degeneration (AMD). METHODS: This was a cross-sectional review of the clinical records and multimodal imaging data of eyes diagnosed with GA secondary to non-neovascular AMD. Imaging modalities included color fundus photography, fundus autofluorescence, NIR, and structural spectral-domain optical coherence tomography (SD-OCT). On SD-OCT images, the foveal retina thickness and the subfoveal choroidal thickness were measured by two independent readers. Near-infrared reflectance intensity within areas of GA was subjectively graded as hyperreflective, isoreflective, or hyporeflective and objectively estimated by using ImageJ to calculate the mean gray scale value within each GA area. A linear regression analysis was performed to model the relationship between mean NIR gray scale value and retinal and choroidal thickness. RESULTS: One hundred four eyes of 104 patients with a mean age of 81.3 years (SD: ±8.3) were included. The area of GA was hyperreflective on NIR in 88 eyes (85%), isoreflective in 13 eyes (12%), and hyporeflective in 3 eyes (3%). The mean foveal retinal thickness was 101.5 μm (SD: ±54) showing no significant relationship with mean NIR (P = 0.464); and the mean subfoveal choroidal thickness was 172.6 μm (SD: ±114.7) showing a statistically significant relationship with mean NIR intensity in the linear regression analysis (r = 0.590; r2 = 0.348; P < 0.00001). CONCLUSIONS: Variations in choroidal thickness appear to influence NIR intensity in areas of GA and have the potential to affect image interpretation. The recognition of this relationship may provide useful information regarding choroidal thickness.
引用
- Dolz-Marco R, Gal-Or O, Freund KB, et al. Choroidal Thickness Influences Near-Infrared Reflectance Intensity in Eyes With Geographic Atrophy Due To Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2016. PMID: 27893108. doi:10.1167/iovs.16-20265
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。