文献速递眼底病与葡萄膜炎

使用扫频源光学相干断层扫描成像观察非渗出性年龄相关性黄斑变性中的脉络膜厚度与脉络膜血管密度

Choroidal Thickness and Choroidal Vessel Density in Nonexudative Age-Related Macular Degeneration Using Swept-Source Optical Coherence Tomography Imaging.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2016-01-01

研究纳入非渗出性年龄相关性黄斑变性(AMD)患眼,按有无网状假性玻璃膜疣(RPD)分为两组,每组25眼,使用100-kHz扫频源光学相干断层扫描(SS-OCT)成像并自动分割脉络膜。结果显示两组脉络膜厚度与脉络膜血管密度均呈显著稳定相关,且有RPD眼平均脉络膜厚度和血管密度均显著低于无RPD眼。自动分割与手动分割平均差异为13.7 μm。

要点

  • 自动脉络膜分割算法与手动分割平均差异为13.7 μm。
  • 两组中脉络膜厚度与脉络膜血管密度均呈显著稳定相关。
  • 有RPD眼平均脉络膜厚度和血管密度均显著低于无RPD眼。

核心结论

  • 全自动脉络膜分割算法能够在大范围内捕捉不同的脉络膜厚度模式。
  • 在本样本中,无论有无RPD,脉络膜厚度与大型脉络膜血管密度均存在明确关系。

研究设计与样本

  • 研究纳入诊断为非渗出性AMD的患眼,使用原型100-kHz扫频源光学相干断层扫描仪(Carl Zeiss Meditec,Dublin,CA,USA),中心波长1050 nm。
  • 采用512×512 A扫描、覆盖12×12 mm视网膜区域的OCT立方扫描模式,按有无网状假性玻璃膜疣(RPD)将眼分为两组,每组25眼。
  • 所有扫描使用自动算法分割,另从两组各随机选择5眼进行手动分割。

主要发现

  • 自动算法生成准确的脉络膜厚度图,手动与自动分割平均差异为13.7 μm。
  • 两组中脉络膜厚度与脉络膜血管密度均呈显著稳定相关。
  • 有RPD眼平均脉络膜厚度和血管密度均显著低于无RPD眼。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To analyze the relationship between choroidal thickness and the distribution of choroidal blood vessels in eyes with nonexudative AMD. METHODS: Eyes with a diagnosis of nonexudative AMD were imaged using a prototype 100-kHz swept-source (SS) optical coherence tomography (OCT) instrument (Carl Zeiss Meditec, Dublin, CA, USA) with a central wavelength of 1050 nm. We used an OCT cube scan pattern consisting of 512 × 512 A-scans over a 12 × 12 mm retinal area. The eyes were partitioned into two groups based on the presence or absence of reticular pseudodrusen (RPD). All scans were segmented using an automated algorithm. In addition, five eyes from each of the two groups were randomly chosen for manual segmentation. Binary choroidal vessels maps were generated from suitable OCT choroidal slabs, and the relationship between the density of large choroidal vessels and choroidal thickness was analyzed using an Early Treatment Diabetic Retinopathy Study-like target centered on the fovea. RESULTS: Twenty-five eyes were enrolled in each group. The automated algorithm produced accurate choroidal thickness maps with an average difference between the manual and automated segmentations of 13.7 μm. There was a significant and stable correlation between choroidal thickness and choroidal vessel density across the two groups. Both average choroidal thickness and vessel density were significantly lower in eyes with RPD. CONCLUSIONS: Our fully automated choroidal segmentation algorithm was able to capture the different patterns of choroidal thickness over a wide area. Choroidal thickness has a clear relationship with the density of large choroid vessels in our sample, irrespective of the presence or absence of RPD.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Zheng F, Gregori G, Schaal KB, et al. Choroidal Thickness and Choroidal Vessel Density in Nonexudative Age-Related Macular Degeneration Using Swept-Source Optical Coherence Tomography Imaging. Invest Ophthalmol Vis Sci. 2016. PMID: 27849311. doi:10.1167/iovs.16-20161

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。