文献速递角膜与眼表疾病

圆锥角膜全层基质结构扭曲的定量分析

Quantitation of Stromal Distortion Across the Full Depth of Keratoconic Corneas.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2026-01-01

本研究采用临床光谱域OCT、高分辨线场共焦OCT及二次谐波发生(SHG)显微术,对4例圆锥角膜和4例对照人角膜进行三维成像,定量分析全层基质结构改变。结果显示圆锥角膜中归一化条纹端点(P=0.008)和端点/分支比(P=0.015)显著升高,胶原取向分布改变,且这些结构标志在圆锥区和圆锥外区域均一致。结论提示圆锥角膜可能为全局性基质紊乱而非纯局部病变。

要点

  • 圆锥角膜SHG图像显示归一化条纹端点和端点/分支比显著升高。
  • 胶原取向由对照的双正交主取向变为单一广泛分布取向。
  • 结构改变在圆锥区和圆锥外区域均一致,支持全局性基质紊乱。

核心结论

  • 圆锥角膜存在全层基质结构扭曲,可能作为早期检测的生物标志物。
  • 结构改变支持基质刚度下降和角膜双折射增加。
  • 结构改变支持全局性基质紊乱而非纯局部病变。

研究设计与样本

  • 探索性初步系列研究,纳入4例圆锥角膜和4例对照人角膜。
  • 联合临床光谱域OCT、高分辨线场共焦OCT和SHG显微术进行三维成像。
  • 使用自动图像分析流程从SHG图像计算结构指标。

主要发现

  • 归一化条纹端点显著升高(P=0.008)。
  • 端点/分支比显著升高(P=0.015)。
  • 圆锥角膜胶原取向呈单一广泛分布,对照呈两个主正交取向。
  • 结构标志在圆锥区和圆锥外区域均保持一致。

临床怎么用

  • SHG定量结构指标可能辅助圆锥角膜早期检测。
  • 评估时需关注全角膜基质改变,而非仅圆锥区。

局限性

  • 样本量小(4例圆锥角膜和4例对照),为初步探索性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed at gaining new insights into the pathophysiology of keratoconus by providing a comprehensive and quantitative characterization of stromal structural alterations throughout the full thickness of keratoconic corneas and in regions both proximal to and distant from the cone. METHODS: Complementary three-dimensional imaging techniques were combined in a pilot exploratory series of four keratoconic and four control human corneas: clinical spectral-domain optical coherence tomography, highly-resolved line-field confocal optical coherence tomography and second harmonic generation (SHG) microcopy. Several structural metrics were computed from SHG images using automatic image analysis pipelines. RESULTS: Quantitative SHG imaging revealed striking structural shifts in keratoconic corneas compared to healthy controls. Most notably, we observed a significant rise in normalized striation Endpoints (P = 0.008) and End/Branch ratio (P = 0.015), consistent with the presence of wavy lamellae and the loss of the plywood-like structure found in control corneas. Importantly, these structural markers remained consistent in both the cone and outside the cone regions. Quantitative processing of collagen orientation revealed a single widely-spread orientation as opposed to two main orthogonal orientations in control corneas, and slight shifts in orientation between superimposed lamellae rather than the abrupt changes observed in control corneas. CONCLUSIONS: We provide new quantitative data on the structural alterations associated with keratoconus that could serve as useful biomarkers for earlier detection. Our findings are consistent with a decreased stromal stiffness and an increase in the corneal birefringence. They are also in favor of a global stromal disorder rather than a purely localized disorder.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Nyembo Kasongo P, Ghoubay D, Allain JM, et al. Quantitation of Stromal Distortion Across the Full Depth of Keratoconic Corneas. Invest Ophthalmol Vis Sci. 2026. PMID: 42924991. doi:10.1167/iovs.67.12.58

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。