文献速递青光眼神经眼科

青光眼视觉处理受损的双重机制:静息态与任务态脑电研究

Dual Mechanisms of Impaired Visual Processing in Glaucoma: Insights From Resting-State and Task-Related EEG.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2026-01-01

发现青光眼组高α频段(10.0-12.9 Hz)α抑制显著降低,P100和N75-P100潜伏期延迟、波幅降低;α抑制缺陷与青光眼严重程度及VEP参数无显著相关。

要点

  • 青光眼组高α频段(10.0-12.9 Hz)α抑制显著降低,低α频段调制保留。
  • 青光眼组P100和N75-P100潜伏期延迟、波幅降低,提示视觉处理受损。
  • α抑制缺陷与青光眼严重程度及VEP参数无显著相关。

核心结论

  • 青光眼患者静息态和任务态脑电均与对照组存在差异,提示皮质活动和视觉通路反应改变。
  • 高α频段α抑制缺陷提示青光眼存在超越直接视觉通路损伤的独特神经生理机制。

研究设计与样本

  • 静息态脑电记录睁眼和闭眼各3分钟,以α抑制(睁眼与闭眼条件下α功率差值)评估认知状态转换能力。
  • 任务态采用64通道脑电系统记录棋盘格翻转任务下单眼和双眼观看的视觉诱发电位。

主要发现

  • 静息态脑电显示青光眼组α抑制显著降低,且高度特异于高α频段(10.0-12.9 Hz;P < 0.001),低α频段(7.0-9.9 Hz)调制保留。
  • 任务态脑电显示青光眼组P100和N75-P100成分潜伏期延迟、波幅降低。
  • 效应量分析显示P100波幅和N75-P100潜伏期的组间差异最大。
  • α抑制缺陷与青光眼严重程度或VEP参数无显著相关。

临床怎么用

  • 静息态高α频段α抑制和任务态VEP(P100波幅、N75-P100潜伏期)可作为评估青光眼皮质活动改变的脑电指标。
  • α抑制缺陷与VEP参数不相关,提示临床评估需同时关注静息态和任务态脑电以全面反映青光眼神经生理改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To examine both resting-state and task-related electroencephalography (EEG) changes associated with visual processing in glaucoma. METHODS: Thirty glaucoma patients (mean age, 63 ± 8.26 years; visual field mean deviation, -15.41 ± 6.34 dB) and 28 age-matched controls (62.86 ± 9.19 years) underwent resting-state EEG for 3 minutes under eyes-open and eyes-closed conditions. Alpha suppression, calculated as the difference between conditions, was assessed as a measure of cognitive state transition capacity. Visual evoked potentials (VEPs) were recorded using a 64-channel EEG system during a checkerboard reversal task under monocular and binocular viewing. RESULTS: Resting-state EEG revealed that significantly reduced alpha suppression was highly specific to a high-alpha subband (10.0-12.9 Hz; P < 0.001), and low-alpha (7.0-9.9 Hz) modulation remained intact in the glaucoma group. Task-related EEG showed delayed latency and reduced amplitude in both P100 and N75-P100 components in the glaucoma group, indicating impaired visual processing. Effect size analysis indicated that P100 amplitude and N75-P100 latency showed the largest group differences, highlighting these as the most prominent cortical changes. Notably, alpha suppression deficits showed no significant correlation with glaucoma severity or VEP parameters, suggesting distinct neurophysiological mechanisms beyond direct visual pathway damage. CONCLUSIONS: Both resting-state and task-related EEG measures differed between the glaucoma and control groups, indicating alterations in cortical activity and visual-pathway responses. Specifically, the localized high alpha modulation deficit suggests altered top-down visual network dynamics in glaucoma.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Mei X, Chen L, Chan LH, et al. Dual Mechanisms of Impaired Visual Processing in Glaucoma: Insights From Resting-State and Task-Related EEG. Invest Ophthalmol Vis Sci. 2026. PMID: 42820801. doi:10.1167/iovs.67.12.2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。